Transmission Products (T-1201)

Ohio Brass® — Protecta*Lite® Data Sheet

Utility Name: ___________________________________________________________________________________________________ Requested By: ______________________________________________ Date: ___________________________________________ Line Name: ___________________________________________________________________________________________________ Line Location (County, State, Country): ____________________________________________________________________________  New Line  Single Circuit  Existing Line  Double Circuit Actual Miles of Line (Report is based on 100 miles) :________________________________________________________________ Line to Line System Voltage: Voltage Regulation (Percent): ______ System Configuration:  Wye (Star)  Delta System Neutral:  Grounded  Ungrounded/Impedance Grounded Max Fault Current (kA):_________________________________ Duration of Fault (cycles):_ ______________________________  Station Class  Intermediate Class  Metal Oxide Varistor  Silicon Carbide _ _____ Duty Cycle (kV) _ ______MCOV (kV) Present Structure Footing Resistance (Ohms):____________________________________________________________________ Alternate Structure Footing Resistance to be Analyzed (Ohms):___________________________________________________ Span Length (ft):_____________________________ Structure Grounds are Located Every (ft): _ _________________________ Soil Resistivity (Ohm-meters) / Dielectric Constant: _____ / _____ Rich Agricultural Land 100 / 15 Pastoral Land 200 / 13

PROTECTA*LITE ® DATA SHEET

Marshy Forest Flat Land 125 / 12 Rocky Hills or Dry Sand 500 / 10 Gravel (partly air) 100 / 7 Rocky Mountains 1000 / 5 City (residential) 500 / 5

Crushed Coarse Rock (mostly air)

100 / 3  Yes  No

Terrain:

 Flat  Hilly

Natural Shielding:

 Mountainous Conductor Diameter (in), Standing & Type: _ ____________________________________________________________________ Conductor Sag (ft): _ __________________________________________________________________________________________ Does his Line Have an Overhead Shield Wire?:  Yes  No Overhead Shield Wire Diameter (in) & Quantity (1 or 2): _ ________________________________________________________ OHSW Sag (ft): _______________________________________________________________________________________________ Insulator Type, Manufacturer, Catalog #: _ ______________________________________________________________________ Insulator Critical Impulse F/O: Pos.____________________ Neg.____________________ Insulator Bases Bonded to Ground?:  Yes  No (Will use wood arm at 50 kV/ft) Isokeraunic Level or Ground Flash Density: ___________________ = IL or ___________________ = GFD Current Number of Annual Lightning Flashovers /100 Miles: _____________________________________________________ Target Number of Annual Lightning Flashovers /100 Miles: ______________________________________________________ Structure Type (see attached) :___________________________________________________________________________________

Please complete attached sketch of typical configuration, including dimensions.

Page 424 | July 2016