City of Morgan Hill Sewer System Master Plan 2017
Table 3.4 Precipitation Depth‐Duration‐Frequency Sewer System Master Plan City of Morgan Hill
PRELIMINARY
2‐Year
5‐Year
10‐Year
25‐Year
100‐Year
Duration
(in)
(in/hr)
(in)
(in/hr)
(in)
(in/hr)
(in)
(in/hr)
(in)
(in/hr)
5‐min
0.15
1.80
0.20
2.40
0.23
2.76
0.29
3.48
0.37
4.44
10‐min
0.22
1.32
0.28
1.68
0.34
2.04
0.41
2.46
0.53
3.18
15‐min
0.26
1.04
0.34
1.36
0.41
1.64
0.50
2.00
0.65
2.60
30‐min
0.36
0.72
0.47
0.94
0.56
1.12
0.69
1.38
0.90
1.80
1‐hr
0.55
0.55
0.71
0.71
0.85
0.85
1.04
1.04
1.35
1.35
2‐hr
0.85
0.43
1.10
0.55
1.31
0.66
1.61
0.81
2.09
1.05
3‐hr
1.07
0.36
1.39
0.46
1.65
0.55
2.02
0.67
2.62
0.87
6‐hr
1.53
0.26
1.98
0.33
2.37
0.40
2.90
0.48
3.78
0.63
12‐hr
2.06
0.17
2.69
0.22
3.22
0.27
3.97
0.33
5.22
0.44
24‐hr
2.69
0.11
3.51
0.15
4.22
0.18
5.22
0.22
6.91
0.29
2/11/2016
Note:
1. Source: NOAA Atlas 14 Volume 6 version 2 for station MORGAN HILL 2E.
Made with FlippingBook - Online magazine maker