Hoods and Enclosures Fume Hood Fittings and Accessories

Fittings for Fume Hood

External Vacuum Breaker Shipped loose and installed in field.

These WaterSaver brand remote control fittings consist of a brass angle valve with a replaceable seat, an epoxy coated brass nylon color-coded panel flange with angle serrated hose connector, a remote control rod assembly with a plastic flange and a tank nipple, locknut and washer. Fittings may be used on either side of hood. Shipped loose and installed in field.

Fitting Type Air (Orange)

Part Number L3185N-LR-A L3185N-LR-G L3185N-LR-N L3185N-LR-V

Fitting Type

Part Number

External Vacuum Breaker

L112WSA

Gas (Dark Blue) Nitrogen (Brown) Vacuum (Yellow)

These WaterSaver brand remote control fittings consist of a brass angle valve with a replaceable seat, and epoxy coated brass nylon color-coded panel flange with a gooseneck with a vacuum breaker, a remote control rod assembly with a plastic flange and a tank nipple, locknut and washer. Shipped loose and installed in field. Cold Water Fitting for Fume Hood

These WaterSaver brand remote control fittings consist of a brass angle valve with a replaceable seat, and epoxy coated brass nylon color-coded panel flange with a gooseneck without a vacuum breaker, a remote control rod assembly with a plastic flange and a tank nipple, locknut and washer. Shipped loose and installed in field. Cold Water Fitting for Fume Hood

Fitting Type Part Number Cold Water with Vacuum Breaker L3185W-9RSVB

Fitting Type Part Number Cold Water without Vacuum Breaker L3185W-9RS

Fume Hood Alarm

Fan Blower Switch

Each INSTOCK fume hood is fully pre- punched, for the fast and easy installation of this alarm. The TEL AFA-1000 provides a digital read- out of the fume hood face velocity and sounds an alarm when the airflow falls below safe levels. Consisting of a ther- mostat sensor (mounted through the side

Manual fan motor starter switch, toggle style, single pole, with red pilot light, stainless steel cover plate, 1 thermal unit, for 1 HP maximum motor size

Product

Part Number

wall of the fume hood) and a monitor (mounted on the fascia), the unit gives both a visual and audible alarm. A glowing green light signals when conditions are safe. The monitor also contains a test/reset button allowing the user to verify alarm readiness. The TEL AFA-1000 operates on a 9V DC circuit and comes complete with an adapter that is plugged into a pre wired 120 VAC recep- tacle on the roof of the hood.

For use with a 1 HP fan For use with a 2 HP fan

2510FS1P 2510FS2P

Product

Part Number

Fume Hood Alarm

AFA1000/1-MK3