Full Line Product Catalog

#36 (see A below)

#36P1 (see B below)

AIR FLOW CHECK VALVE The industry's leading Check Valve provides needed protection to keep cable air pressure in each pressurized cable. Air Flow Check Valve opens when pressure on manifold side (supply side) of Valve is greater than cable air pressure. Allows free flow of air to cable: instantaneously stops back flow of air. Cable mounting of Check valve recommended inline between manifold and cable. Provides protection should break in plastic tubing occur. can be placed in any position. Made from brass bar stock. Mounts on standard "C" flange type (1/8" female NPT opening. Connects to 3/8" or 1/4" poly-flo plastic tubing.

#36CV4 or 36CV6 (see C, D below)

#36P4 or 36P6 (see E, F below)

MALOR REGULATOR ASSEMBLIES Regulates air pressure from 1-10 psi maximum outlet pressure. Inlet pressure to to 30 psi permissible. Provides necessary protection for air pressure system. Designed to be used as a manual shut-off, also. Ideal for both pole or manhole mounted applications. In manhole, mount on wall or on manifold . The MALOR Regulator is designed with three ports: in, out, and gauge ports (1/8" NPT female). The gauge port is provided for setting ease during installation and for routine maintenance convenience. Compact size, height- 3". Made of cadmium plated brass, the MALOR Regulator's manual shut-off has sensitive thumb screw adjustment feature with lock nut provided to maintain exact setting.

WHEN ORDERING SPECIFY: AIR FLOW CHECK VALVE #30-1/4 AIR FLOW CHECK VALVE #30-3/8

ORDERING INFORMATION FOR REGULATOR ASSEMBLIES:

Description

Part #

A. REGULATOR (only)

36

B. REGULATOR, Mounting Bracket, "F" Pressure Checking Valve C. Regulator with Check Valve, Mounting Bracket, "F" Pressure Checking Valve, 1/4" Plastic Tube Connections D. SAME AS 36CV4 Except 3/8" Plastic tube Connections E. REGULATOR, Mounting Bracket, "F" Pressure Checking Valve, 1/4" Plastic tube Connections F. SAME AS 36P4 Except 3/8"

36P1

CONTROLLED FLOW CHECK VALVE An exclusive MALOR product to protect and safeguard pressurized cables. A MUST for use at all high valve, down valve, and transducer plastic tubing-to-cable connection points. Mounts on standard "C" flange type (1/8" NPT female) opening. Can be placed in any position. Poly-flo plastic tubing connects to Check Valve. Valve allows free flow of air from auxillary air source to pressurized cable. Should tubing from pressure checking valve or transducer become severed, punctured, melted, or otherwise disconnected, Controlled Flow Check Valve constricts air flow out of cable to a minimum controlled amount. (approx. 3/4 -1 SCFH) Back flow adequate when using "C" Pressure Reading Gauge. Severe leak conditions are avoided. WHEN ORDERING SPECIFY:

36CV4

36CV6

36P4

36P6

Plastic Tube Connections G. MOUNTING BRACKET

36B

(not shown)

CONTROLLED FLOW CHECK VALVE #31-1/4 CONTROLLED FLOW CHECK VALVE #31-3/8

MANIFOLD CHECK VALVE Widely used Check Valve available for mounting on cable side of manifold. Plastic tubing 1/4" or 3/8" connects to other end. Features 1/8" NPT, female side entrance on cable side of Check Valve for "F" pressure checking valve placement. Manifold Check Valves sre especially popular for placement on existing plant. Made of brass, 1/8" NPT male on one end to tubing connection on other end. WHEN ORDERING SPECIFY:

CHECK VALVE WITH ELBOW Check Valve with 90° Elbow mounts on "C" Flange (1/8" NPT, female). Elbow permits plastic tubing to be placed out of way parallel to cable. Performance features same as for Air Flow Check Valve #30. Made of brass, connects to 3/8" or 1/4" Poly-flo plastic tubing. WHEN ODERING SPECIFY:

CHECK VALVE, MANIFOLD #3022-1/4 CHECK VALVE, MANIFOLD #3022-3/8

CHECK VALVE, 90° ELBOW #3090-1/4 CHECK VALVE, 90° ELBOW #3090-3/8

For Parts Sales and Technical Support 24-Hours Call 1-800-247-7747 Web: www.clblankenship.com

Made with FlippingBook flipbook maker