EC Meeting November 2018
Date Received by HMC
Date Returned by HMC
Status A=No comments B=Returned with comments C=Resubmit
Drawing No.
Revision Drawing Title
12.07.2018 01.08.2018
A A
M16.241-01 M16.241-02
C2 C2
Sprigg Little Sprigg Little
Hotel extension foundation layout
"
"
Hotel extension GF layout showing construction over
"
"
A
M16.241-03
C2
Hotel extension first floor layout showing construction over Sprigg Little
" " " " " " " " " " " " " " " "
" " " " " " " " " " " " " " " "
A A A A A A A A A A B A B A A A
M16.241-04 M16.241-05 M16.241-06 M16.241-07 M16.241-20 M16.241-21 M16.241-22 M16.241-40 M16.241-41 M16.241-80 M16.241-100 M16.241-101 M16.241-200 M16.241-210 M16.241-211 M16.241-MS
C1 C2 C1 C1 C2 C2 C2 C2 C2 C1 C6 P1 C4 C1 P1
Sprigg Little Sprigg Little Sprigg Little Sprigg Little Sprigg Little Sprigg Little Sprigg Little Sprigg Little Sprigg Little Sprigg Little Sprigg Little Sprigg Little Sprigg Little Sprigg Little Sprigg Little
Hotel extension typical sections and details sheet 1 Hotel extension typical sections and details sheet 2
Goodacre foundation layout
Goodacre GF layout showing construction over New houses foundation layout and details
New houses ground floor layout and first floor construction Sprigg Little
New houses first floor layout and roof construction Training block foundation layout and details Training block ground floor layout and details
General notes
External works layout Typical gabion wall detail Site wide drainage layout Drainage standard details Manhole type P & PX detail
F01
Foul sewer system, manhole schedule (to be read in conjunction with SLP Ltd dwg M16.241.200 Storm sewer system, manhole schedule (to be read in conjunction with SLP Ltd dwg M16.241.200 Storm sewer system, manhole schedule (to be read in conjunction with SLP Ltd dwg M16.241.200
"
"
A
M16.241-MS
S01
Sprigg Little
"
"
A
M16.241-MS
S02
Sprigg Little
30.07.2018 31.07.2018 02.08.2018 13.08.2018 02.08.2018 13.08.2018 03.08.2018 03.08.2018
C C C C
E-01
ECO-1 ECO-1 ECO-1
Electrical services
180062 180062
GFTU first floor power and lighting fire alarm GFTU ground floor power and lighting fire alarm
GMS/5266/M500
P0
external services layout
Gill Mechanical Services Ltd (GMS)
06.08.2018 15.08.2018
A B B B B B B A A C C A A B A A B B B B B B B B A A A C B A C B B A B B A C C C A A
8240-01 8240-02 8240-03 8240-03 8240-100 8240-200 8240-300
B
Acheson + Glover
training block ground floor beam and block
" " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " "
16.08.2018 16.08.2018 15.08.2018 16.08.2018 16.08.2018 16.08.2018 17.08.2018 17.08.2018 17.08.2018 17.08.2018 17.08.2018 17.08.2018 17.08.2018 17.08.2018 17.08.2018 17.08.2018 17.08.2018 17.08.2018 17.08.2018 17.08.2018 17.08.2018 17.08.2018 17.08.2018 17.08.2018 17.08.2018 17.08.2018 17.08.2018 17.08.2018 17.08.2018 17.08.2018 20.08.2018 17.08.2018 17.08.2018 17.08.2018 17.08.2018 15.08.2018 31.07.2018 13.08.2018 13.08.2018 15.08.2018 15.08.2018
" " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " "
1st floor hotel extension 1st floor new housing
Hotel ground floor beam & block Stairwell 2 - hotel extension Stairwell 2 - unit 7 new buildings Stairwell 2 - unit 9 new buildings
17415-1000 17415-2000 17415-2001 17415-2002 17415-2004 17415-2109 17415-2110 17415-2111 17415-2115 17415-2124 17415-2146 17415-2180 17415-2185 17415-2186 17415-2190 17415-2200 17415-2201 17415-2203 17415-2204 17415-2205 17415-2206 17415-2218 17415-2280 17415-2401 17415-2402 17415- 2403 17415-2424 17415-SK-020 17415-SK-021
C 01 C 04 C 01 C 02 C 01 C 01 C 01 C 00 C 00 C 00 C 01 C 00 C 00 C 03 C 02 C 01 C 01 C 02 C 02 C 00 C 01 C 00 C 00 C 00 0 0 0 0 0 0
Corstorphine + Wright
Training block - demolition plan & elevations
Proposed site setting out plan
Proposed site setting out plan sheet 1 Proposed site setting out plan sheet 2 Proposed site plan tree removal plan Hotel proposed ground floor plan Hotel proposed first floor plan Hotel proposed ground floor plan Hotel proposed sections shet 1 Hotel proposed stair 2 detailed layout Proposed hotel - stonework details
Proposed hotel setting out plan
Hotel proposed ground floor plan furniture & finishes
Hotel proposed first floor plan furniture & finishes Proposed garage & tank setting out plan Training block proposed ground floor plan Training block proposed first floor plan Training block proposed elevations - north & south Training block proposed elevations - east & west
Training block GA sections - archive Training block GA sections - training room
Training block kitchen layout
Proposed training block setting out plan
Residential units - ground floor Residential units - first floor Residential units - first floor
Residential units - stair detailed layouts
0 1
Hotel extention - GF drainage Hotel extention - FF drainage
C 01
QG EV 001
A
Datum ECO-1 ECO-1 ECO-1
Elevation survey Electrical services
E-01
180062 180062 18-5477
GFTU ground floor power and lighting fire alarm GFTU first floor power and lighting fire alarm Calculations for gabion retaining walls 01-03
A 1
Maccaferri
SK001
MLB Eng
Plan view
[ 1/3 ]
Made with FlippingBook - Online Brochure Maker