NEMA FULL VOLTAGE POWER DEVICES, CONTROL SECTION 1

1-40

— Enclosed combination magnetic starters CR308 non-reversing, disconnect switch

Ordering code configuration Valid for NEMA sizes 0–2, type 1 standard enclosure

Digits:

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

C R

Steps:

Step 1

Step 2

Step 3

Step 4 Step 5 Step 6 Step 7 Step 8 Step 9

To configure the ordering code, use the tables below to fill in the digit boxes with the appropriate code.

— Step 3 (digits 10, 11) select protective device (continued)

— Disconnect with class R fuse clips — for use with time delay/dual element class RK1/RK5 fuses

200–208 V

230–240 V

460–480 V

575–600 V

Fuse clip (amps)

Fuse clip (amps)

Fuse clip (amps)

Fuse clip (amps)

NEMA size

Max. hp

Code Max. hp

Code Max. hp

Code Max. hp

Code

0 1

3 5

30 30 60 60

RA RA RB RB

3 5

30 30 60 60

RA RA RB RB

5

30 30

R3 R3

5

30 30

R3 R3

10

10

7 1 ⁄

7

1 ⁄

– –

2

2

2

10

15

30 60

R3 R6

15 25

30 60

R3 R6

25

— Disconnect with class J fuse clips — for use with time delay/dual element class J fuses

200–208 V

230–240 V

460–480 V

575–600 V

Fuse clip (amps)

Fuse clip (amps)

Fuse clip (amps)

Fuse clip (amps)

NEMA size

Max. hp

Code Max. hp

Code Max. hp

Code Max. hp

Code

0 1

3 5

30 30 60 60

J3 J3 J6 J6

3 5

30 30 60 60

J3 J3 J6 J6

5

30 30

J3 J3

5

30 30

J3 J3

10

10

7 1 ⁄

7

1 ⁄

– –

2

2

2

10

15

30 60

J3 J6

15 25

30 60

J3 J6

25

— Step 4 (digit 12) select overload relay Overload relay Thermal bi-metallic ambient compensated (1 NC) Thermal bi-metallic ambient compensated (1 NO–1 NC)

Code

3 4

Solid state overload (1 NO–1 NC)

(#)

(#) Select code for solid state overload amp rating from standard or optional ranges table below.

— Solid state overload relay — standard range

— Optional ranges

200–208 V 575–600 V Max. hp Code Max. hp Code Max. hp Code Max. hp Code 230–240 V 460–480 V

NEMA size

NEMA size OL range

OL amp range

0 and 1

2 – – – – G H

3 ⁄

D E

1 2 5

D E

0

0.8–1.7 1.6–3.4 3.2–6.8 6.5–13.5 6.5–13.5

0.4–0.85 0.8–1.7 1.6–3.4 3.2–6.8 6.5–13.5 13–27 25–50 17–35 35–70 65–135

C D E F G H

4

1 ⁄

E F G

3 ⁄

E F G

2 3 5

2

4

1 3

2 3

F

F –

G G H H

7 1 ⁄

10

G

1

2

13–27 13–27 25–50

7 1 ⁄

H

7

1 ⁄

H

10 20 25

2

2

– – – –

J – – –

2

– J

– J

25

H

10

15

J

Please reference the NEMA full voltage power devices catalog for additional technical data, selection and installation guides, and dimensional drawings.