Control_Flippingbook_NOV 2024
NEMA FULL VOLTAGE POWER DEVICES, CONTROL SECTION 1
1-53
— Enclosed combination magnetic starters CR387 non-reversing, instantaneous trip circuit breaker
Ordering code configuration Valid for NEMA sizes 0–2, type 1 standard enclosure
Digits:
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
C R
Steps:
Step 1
Step 2
Step 3
Step 4 Step 5 Step 6 Step 7 Step 8 Step 9
To configure the ordering code, use the tables below to fill in the digit boxes with the appropriate code.
— Step 7 (digit 15) select pushbutton/ selector switch Pushbutton/selector switch - heavy duty
— Step 6 (digit 14) select monitoring options Device
— Step 5 (digit 13) select auxiliary contacts Auxiliary contacts
Code
Code
Code
None 1 NO 1 NC
A B C D E F G H
None 2
A
None
A
Start/stop pushbutton
J
2 Phase failure relay is not available for CR387 series standard enclosures. If this is required for your application, use CR487 series oversized enclosure.
Hand-off-auto (HOA) selector switch
L
1 NO–1 NC
Off-on selector switch
M
2 NO 2 NC
HOA selector switch and start pushbutton
S
Keyed HOA selector switch, key removal center pos.
N
2 NO–1 NC 1 NO–2 NC
3 NO 3 NC 4 NO 4 NC
J
K
L 1
M 1 N 1
2 NO–2 NC 3 NO–1 NC 1 NO–3 NC
P 1
R 1 1 Exceeds maximum number of contacts for some pilot light selections. See step 8 (digit 16).
— Step 8 (digit 16) select pilot device Pilot light (heavy duty) type
Color — functionality
Code
None
A 1 2
LED lights
Red — across coil Green — across coil
Red — thru NO aux contact Green — thru NC aux contact
3 3 4 3 5 4 6 3 7 3 C 3 D 3 E 4 V 3 Y 3 R S
Red — thru NO aux contact and green — thru NC aux contact Red — across coil and green — thru NC aux contact Red — across coil and green — thru NC aux contact and unwired amber
Push-to-test lights
Red — across coil Green — across coil
Red — thru NO aux contact Green — thru NC aux contact
Red — thru NO aux contact and green — thru NC aux contact Red — across coil and green — thru NC aux contact Red — across coil and green — thru NC aux contact and unwired amber
3 Maximum of 3 aux contacts may be added to sizes 0 and 1. 4 Maximum of 2 aux contacts may be added to sizes 0 and 1. Maximum of 3 aux contacts may be added to sizes 2–4. Note: Auxiliary contacts wired as part of pilot light selection are in addition to the auxiliary contacts selected from step 5 (digit 13), which are for customer/field connections.
— Step 9 (digit 17) select control options Device
Code
None
A
General note: If selecting factory installed and wired operator devices (pushbuttons, selector switches and/or pilot lights), control circuit fusing, a control power transformer or 24 V/120 V separate sourced control is required, regardless of protective device rating.
Made with FlippingBook - Online Brochure Maker