Total Collaborative Study Protocol_Solus One Salmonella v1 1
The original validation study was conducted under the AOAC Research Institute Performance Tested
Method SM protocol and the AOAC INTERNATIONAL Methods Committee Guidelines for Validation of
Microbiological Methods for Food and Environmental Surfaces (3). Method developer studies were
conducted in the laboratories of Solus Scientific Solutions, located in East Kilbride, Scotland, and
included the product consistency and stability studies, and robustness testing. The independent
laboratory study was conducted by Q Laboratories, located in Cincinnati, Ohio, and included the
inclusivity/exclusivity study, and matrix studies for all claimed food and environmental surface matrices.
The Solus One Salmonella method (AOAC Performance Tested Method SM 101801) was compared to
the FDA/BAM Chapter 5 for raw salmon (fillet), cheddar cheese (shredded), Romaine lettuce (bagged),
non‐fat dry milk powder and both stainless steel and plastic environmental surfaces. In addition, the
Solus One Salmonella method was compared to the MLG 4.09 for raw beef (trim) and pasteurized eggs.
Independent laboratory study samples were analyzed using both the manual and automated
immunoassay sample preparation methods, which use identical reagent volumes and incubation
conditions for processing samples following enrichment, for the detection of Salmonella from cheddar
cheese (shredded) and stainless steel environmental surfaces, whereas all method developer study
samples were analyzed using the automated immunoassay sample preparation method. Regardless of
which method was used to prepare the test portions, all samples were read using the Dynex DS2
instrument, using the “Plate Read Only” program for the manual method.
This report details the method modification study to extend the matrix claim to herbs, spices and
flavorings. The Solus One Salmonella method was compared to the FDA/BAM Chapter 5 for honey
mustard onion seasoning, flavored ranch seasoning, cinnamon powder, paprika powder and whole black
peppercorns where independent laboratory study samples were analyzed using the automated
preparation method. Because of the inhibitory components within spice and flavor matrices, the
Page 22 of 39
Made with FlippingBook - Online Brochure Maker