Micro December 2018
1
( c ) Summary of Validated Performance Claims. —The 3M Petrifilm Rapid E. coli/ Coliform
Count Plate is considered equivalent to the U.S. Food and Drug Administration (FDA) 2
Bacteriological Analytical Manual (BAM), Chapter 4, Enumeration of Escherichia coli and the 3
Coliform Bacteria (1), ISO 4832:2006, Microbiology of food and animal feeding stuffs -- 4
Horizontal methods for the enumeration of coliforms -- Colony-count technique (2) and ISO 5
16649-2:2001, Microbiology of food and animal feeding stuffs -- Horizontal methods for the 6
enumeration of beta-glucuronidase-positive Escherichia coli -- Part 2: Colony-count technique at 7
44 degrees C using 5-bromo-4-chloro-3-indolyl beta-D-glucuronide (3) for a broad range of foods 8
9
and select environmental surfaces.
10
11
Definitions
12
13
( a ) Difference of Means. —Difference in log 10 of the average results between the
candidate and reference method for one level of contamination . 14
15
( b ) Repeatability. —Precision where independent test results are obtained with the same
method on equivalent test items in the same laboratory by the same operator using the same 16
17
equipment within short interval of time .
18
( c ) Relative Standard Deviation. —The ratio of the standard deviation to the mean, often
19
reported in percentage.
20
21
General Information
22
4