3. Cavitation strength of primary coatings 3.1 Cavitation strength test The physical concept of cavitation strength as described in 2.1.2 is the critical tri-axial stress level at which a material starts to rupture. A test method has been developed to measure the cavitation strength of a coating material from a cured film. 3.1.1 Measurement setup . In principle the way to induce tri-axial tensile stress in a coating material is straightforward: increase the volume of the rubber-like coating material. The coating is cured and adhered between two flat surfaces, which are separated in a tensile testing machine. With the controlled increase of the distance between the two plates, a tri-axial tensile stress is generated in the coating. The setup is designed so that the coating thickness is less than 5% of the diameter of the plates. Because this very thin layer of coating is bounded to the plates, the sideway contraction of the coating is restricted. Consequently, a tri-axial tensile stress is created uniformly in the coating material. In order to obtain reproducible values of the cavitation strength, the alignment of the setup is important, since this affects the stress distribution in the sample. Furthermore, to be able to study the development of the amount of cavities with the load in a reproducible way, the stiffness of the setup should be high (ie the compliance should be low) in order to minimise the storage of elastic energy in the measurement setup. 3.1.2 Sample preparation. The sample setup is illustrated in Figure 8. To avoid de-lamination during the course of the experiment, the surfaces of the glass plates and the quartz

to the force direction are stretched. The tensile stress in these stretched areas has a significant tri-axial component that may cause primary coating cavitation if the stress exceeds the cavitation strength of the coating. Figure 6 demonstrates a mean normal stress field calculated by Finite Element Analysis in the primary coating layer of a fibre with OD geometry of 125/240/410 μm under a simulated lateral force condition. The result quantitatively shows different stress fields varying from compressive (-) to tensile (+). As shown in Figure 6 , the areas under the highest tensile stress are the spots perpendicular to the direction of the applied force and close to either side of the interfaces between glass and primary coating and between primary coating and secondary coating. These areas are where the cavitation would most likely start under applied mechanical lateral force. Figure 7 shows some examples of inten- tionally induced cavities in the primary coating formed by mechanical lateral impacts. The lateral force has to be dynamic with the speed, either along the fibre (sliding) or perpendicular to the fibre (hitting). A static lateral force can only result in de-lamination. In Figure 7 , the mechanical impact was created by sliding a 1mm diameter metal rod along the fibre direction. A fixture was made attaching the metal rod to an automatic rub tester with controlled speeds and controlled forces by adding different weights on the fixture. Both force level and impact speed influence the stress state in the coating. At very slow speeds, de-lamination occurs rather than coating cavitation. This may be because the small de-lamination area formed at the initial contact of the force propagates along the fibre and releases the tensile stress in the coating. At medium to high speeds, cavities and/or de-lamination can be formed as shown in Figure 7 . The cavities are localised on the two side areas, which is in agreement with the theory. two competing failure modes. They may appear individually or simultaneously, depending on the properties of adhesion level and cavitation strength of a particular coating. The adhesion level of primary coating on glass should be balanced with the strip force requirement. A high cavitation strength is always desirable for a primary coating to im- prove the robustness of the coated fibre. One should be aware, however, any coated fibre will eventually fail in the form of de-lamination and/or cavitation when the mechanical impact is elevated to a certain level. While thermal stress is intrinsic from the dual-layer design, mechanical stress comes from external sources. Any abnormal high-pressure impacts on fibres should be avoided during the fibre drawing, spooling, proof-testing and handling processes. Cavities and de-lamination are

billets have to be properly prepared. First the surfaces were roughened by polishing using a carborundum powder. The glass and quartz pieces were then burned clean in an oven at 600ºC for one hour, and the surfaces were rinsed with acetone and allowed to dry. Subsequently, the surfaces were treated with a solution of a silane adhesion pro- moter – Methacryloxypropyltrimethoxysilane (A174 from Witco) was used. The silane layer was cured by placing the treated glass or quartz plates in an oven at 90ºC for 5-10 minutes. After this pre-treatment, a droplet of resin was disposed onto the glass plate and covered with the quartz billet. The film thickness is set to approximately 100 μm using a two-plate micrometer. The sample was cured with a 1 J/cm 2 dose, using a Fusion F600W UV-D lamp system. 3.1.3 Measurement of the cavitation strength. The sample was placed in the tensile testing apparatus (Zwick type 1484). The pulling speed was 20 μm/min. When an experiment was started, a video camera, attached to a microscope with 20x magnification, recorded the behaviour of the film, while also showing the stress level being exerted on the film. Figure 9 shows an image of the sample, captured by the video camera, with many cavities already formed. From the videotape, the number of cavities appearing as a function of the applied stress was plotted as illustrated in Figure 10 . It was found that the stresses at which the first cavity was observed were all at a similar level for different coating materials. However, the stress levels started to exhibit clear differences among different coatings, as more cavities were formed. In this test method, the stress value corresponding to the formation of 10 cavities was selected to represent the cavitation strength of the measured coating.

Figure 7 ▼ ▼ : Examples of cavity/delamination formation in the primary coating layer by mechanical lateral impact

Figure 8 ▼ ▼ : Sample set up of the cavitation strength test

62