Underbridge Catalog
FIGURE 16b
stop ring
continue strand to next 200’
150’
stop ring location
stranding can begin and end at intermediate hangers- do not cross bridge expansin joints-stranding cableshould never be longer than 200 feet
anchor type supports should be used at all stop ring and expansion joint locations
brace angle not to exceed 45 deg from horizontal
A
A
A
split stop ring lit stop ring
expansion joint sleeve sion joint sleev
nipple i ple
step A
step B
step C
jointer piece
split stop ring cemented or epoxied to conduit line
nipple
expansion joint sleeve
nipple
cement or epoxy cement or epoxy
split stop rings
cement or epoxy
support
second support
single action expansion sleeve