Underbridge Catalog

FIGURE 16b

stop ring

continue strand to next 200’

150’

stop ring location

stranding can begin and end at intermediate hangers- do not cross bridge expansin joints-stranding cableshould never be longer than 200 feet

anchor type supports should be used at all stop ring and expansion joint locations

brace angle not to exceed 45 deg from horizontal

A

A

A

split stop ring lit stop ring

expansion joint sleeve sion joint sleev

nipple i ple

step A

step B

step C

jointer piece

split stop ring cemented or epoxied to conduit line

nipple

expansion joint sleeve

nipple

cement or epoxy cement or epoxy

split stop rings

cement or epoxy

support

second support

single action expansion sleeve

www .OSBURNS. com • TOLL-FREE 1-800-523-8917 • TEL (740) 385-6869 • FAX (740) 385-8016

7

Made with FlippingBook - Online Brochure Maker