Northrock PPE Catalogue- Australia Edition
WORKING IN EXTREME COLD
EN 342
EN342 protection against cold is the most comprehensive standard test method for clothing designed to protect you in cold conditions. The principle test uses a heated manikin, a thermal insulation value is determined from the power required to maintain the manikin at a constant temperature. This value is used to classify the performance of the garment. This insulation value of the clothing, the activity level of the wearer and the temperature of the environment can be used to estimate the maximum duration of wear. Clothing that meets the requirement of EN342 will have this pictogram on the label. EN 342 STANDARD AND THERMAL MANIKIN TESTING 0.433
EN342 - RECOMMENDED MAXIMUM CONTINUOUS WEARING TIME The below diagrams shows the length of time and the temperature at which the garment can be worn, maintaining wearer comfort at a particular activity level. Resultant effective thermal insulation of clothing Iclear, and ambient temperature conditions for heat balance at different durations of exposure.
Wearer Activity Level
No Wearer Activity
Light Wearer Activity
Medium Wearer Activity
Air Velocity (metres per second m/s)
0.4
3
0.4
3
0.4
3
Garment Insulation (Icler m²K/W) This value is under each style code tested to EN342
Time in Hours
8hr 1hr 8hr 1hr 8hr 1hr 8hr 1hr 8hr 1hr 8hr 1hr
13°C 0°C 19°C 7°C 3°C -12°C 9°C -3°C -12°C -28°C -2°C -16°C 10°C -4°C 17°C 3°C -2°C -18°C 6°C -8°C -18°C -36°C -7°C -22°C 5°C -12°C 13°C -3°C -9°C -28°C 0°C -16°C -29°C -49°C -16°C -33°C 0°C -20°C 7°C -9°C -17°C -38°C -6°C -24°C -40°C -60°C -24°C -43°C -5°C -26°C 4°C -14°C -24°C -45°C -11°C -30°C -49°C -71°C -32°C -52°C -10°C -32°C 0°C -20°C -31°C -55°C -17°C -38°C -60°C -84°C -40°C -61°C
0,265
0,310
0,390
Temperature °C
0,470
0,540
0,620
EN342 COLD TEMPERATURE RANGE This example shows that a worker can wear the garment specified for a medium level activity for 8 hours at -35°C or for 1 hour at -55°C.
-35 0 C / 8 hr -55 0 C / 1 hr
Portwest Huski Example
K8044 Jacket + K8047 Trouser
Garment Insulation (Icler m²K/W):
0.433 Icler
Wearer Activity Level
No Wearer Activity
Light Wearer Activity
Medium Wearer Activity
Air Velocity (m/s)
0.4
3
0.4
3
0.4
3
Time in Hours
8hr
1hr
8hr
1hr
8hr
1hr
8hr
1hr
8hr
1hr
8hr
1hr
Temperature °C Results for the above garments
2°C -17°C 10°C -6°C -13°C -34°C -3°C -20°C -35°C -55°C -20°C -38°C