MSC - Erection Manual

MSC M echanically S eamed C onstruction

®

DETAILS

HIP TRIM

RIDGE/HIP FLASH

"Z" CLOSURE (Field cut to length and bevel cut to fit panel) SIKA 201 3" X 3" 16 GA. BACK-UP ANGLE

2" ±2"

1/4"-14 X 7/8" WT (5" C.C.) TRI-BEAD TAPE MASTIC PANEL CLIP W/FASTENERS (SEE ROOF PANEL PLAN)

MSC PANEL

PURLIN

#12-14 X 1" PANCAKE HEAD (2 PER PURLIN)

MIN. 16 GA. PLATE HIP SUPPORT 1/8" X 3/8" BLIND RIVET (4" C.C.)

1/4"-14 X 7/8" WT (5" C.C.)

RIDGE/HIP FLASH

MSC PANEL

SIKA-201

MIN. 16 GA. PLATE HIP SUPPORT

"Z" CLOSURE (Field cut to length and bevel cut to fit panel) 1/8" X 3/8" BLIND RIVET (4" C.C.)

TRI-BEAD TAPE MASTIC

A-20-B ANGLE 6" LONG (2)#12-14 X 1 1/4"

3" x 3" X 16 GA. ANGLE

EAVE STRUT

EAVE STRUT

REFER TO ERECTION DRAWINGS FOR PART CALL OUTS

CAUTION All trapezoidal panels are extremely difficult to install at hips and valleys in a weathertight manner. The use of these details should only be attempted by installation crews that are highly experienced. In order to help ensure weathertightness, CHIEF recommends it’s MVF / MVP standing seam system for use on roofs that require hips and valleys.