Proefschrift_vd_Beek

Frijns, J. H. M., de Snoo, S. L., & Schoonhoven, R. (1995). Potential distributions and neural excitation patterns in a rotationally symmetric model of the electrically stimulated cochlea. Hearing Research , 87 , 170–186. Frijns, J. H. M., de Snoo, S. L., & ten Kate, J. H. (1996). Spatial selectivity in a rotationally symmetric model of the electrically stimulated cochlea. Hearing Research , 95 , 33–48. Frijns, J. H. M., Klop, W. M., Bonnet, R. M, & Briaire, J. J. (2003). Optimizing the number of electrodes with high-rate stimulation of the clarion CII cochlear implant. Acta Oto-laryngologics , 123 , 138–142. Gomaa, N. A., Rubinstein, J. T., Lowder, M. W., Tyler, R. S., & Gantz, B. J. (2003). Residual speech perception and cochlear implant performance in postlingually deafened adults. Ear & Hearing , 24 , 539–544. Hamzavi, J., Baumgartner, W. D., Pok, S. M., Franz, P., & Gstoettner, W. (2003). Variables affecting speech perception in postlingually deaf adults following cochlear implantation. Acta Oto-laryngologics , 123 , 493–498. Hochberg, I., Boothroyd, A., Weiss, M., & Hellman, S. (1992). Effects of noise and noise suppression on speech perception by cochlear implant users. Ear & Hearing , 13 , 263–271. Hochmair, I., Arnold, W., Nopp, P., Jolly, C., Muller, J., & Roland, P. (2003). Deep electrode insertion in cochlear implants: apical morphology, electrodes and speech perception results. Acta Oto-laryngologics , 123 , 612–617. Hughes, M. L. (2003). The relationship between electrophysiologic measures of channel interaction and electrode discrimination ability in cochlear implant recipients. Ph.D. Thesis, University of Iowa, USA. Lefrancois, R. D., & Moran, L. M. (2003). Bacterial meningitis in children with cochlear implants. New. England Journal of Medicine , 349 , 1772–1773. Marrinan, M. S., Roland, J. T., Jr., Reitzen, S. D., Waltzman, S. B., Cohen, L. T., & Cohen, N. L. (2004). Degree of modiolar coiling, electrical thresholds, and speech perception after cochlear implantation. Otology & Neurotology , 25 , 290–294. Mens, L. H., Boyle, P. J, &Mulder, J. J. (2003). The Clarion Electrode positioner: approximation to the medial wall and current focussing? Audiology & Neuro-otology , 8 , 166–175. Nadol, Jr., J. B. & Eddington, D. K. (2004). Histologic evaluation of the tissue seal and biologic response around cochlear implant electrodes in the human. Otology & Neurotology , 25 , 257–262. Parkinson, A. J., Arcaroli, J., Staller, S. J., Arndt, P. L., Cosgriff, A., & Ebinger, K. (2002). The nucleus 24 contour cochlear implant system: adult clinical trial results. Ear & Hearing , 23 ,41S–48S. Pasanisi, E., Vincenti, V., Bacciu, A., Guida, M., & Bacciu, S. (2002). The nucleus contour electrode array: an electrophysiological study. Laryngoscope , 112 , 1653–1656. Reefhuis, J., Honein, M. A., Whitney, C. G., Chamany, S., Mann, E. A., & Biernath, K. R. (2003). Risk of bacterial meningitis in children with cochlear implants. New England Journal of Medicine , 349 , 435–445. Richter, B., Aschendorff, A., Lohnstein, P., Husstedt, H., Nagursky, H., & Laszig, R. (2002). Clarion 1.2 standard electrode array with partial space-filling positioner: radiological and histological evaluation in human temporal bones. Journal of Laryngology & Otology , 116 , 507–513. Roland, Jr., J. T., Fishman, A. J., Alexiades, G., & Cohen, N. L. (2000). Electrode to modiolus proximity: a fluoroscopic and histologic analysis. American Journal of Otolaryngology , 21 , 218–225. Saunders, E., Cohen, L., Aschendorff, A., Shapiro, W., Knight, M., & Stecker, M. (2002). Threshold, comfortable level and impedance changes as a function of electrode-modiolar distance. Ear and Hearing , 23 , 28S–40S. Ramsden, R. T. (2004). Prognosis after cochlear implantation. BMJ , 328 , 419–420.

3

65

Made with