Conversion Catalogue
KHS Innopro
KHS Innopro CMX – DRY-RUNNING PUMP UPGRADE
TECHNICAL UPGRADE
EN
Suitability
For all Innopro Paramix CMX and
DCX machines that are suitable
for conversion from "wet-
running" to "quasi dry-running"
vacuum pumps from Gardner
Denver/Elmo Rietschle.
Description
Scope of supply
The standard wet-running vacuum pump used to generate the necessary
Vacuum pump and modification of
negative pressure (vacuum) for water deaeration is replaced by a quasi dry-
the vacuum piping
running vacuum pump. This almost completely eliminates the continuous
Stainless steel frame
supply of sealing water required to date. In addition, the still remaining
Wiring/piping materials
requirement of manually changing the water of dry-running pumps at regular
Modification of the automation,
intervals (every 4–8 weeks) can be fully automated.
software and visualization systems
required for operation
Modification of the machine
Benefit
documentation
Pneumatically actuated valves
Tremendous sealing water savings
Software module
Elimination of the necessity of providing a continuous supply of sealing
Reminder function
water
Less burden on the wastewater system
Contact
Economic efficiency calculation
fred.burkat@khs.com
Example of a conversion:
Existing Paramix system: Capacity: 43,000 l/hr
Product: CSDs
Continuous water consumption to date: approx. 450 l/hr @ 1,665 m3/year
(230 days of production per year x 16 hrs/day = approx. 3,700 hrs)
Cyclic water consumption after conversion: approx. 150 liters per water change
@ 1.8 m3/year
Water savings: 1,663 m3/year
KHS GmbH
Juchostraße 20
D-44143 Dortmund
* Subject to technical modifications and price changes. On
Deutschland
request, we will be glad to provide you with a binding offer.
Tel: +49.231.569 0
info@khs.com Version 1 Date 29.07.2014