Conversion Catalogue

KHS Innopro

KHS Innopro CMX – DRY-RUNNING PUMP UPGRADE

TECHNICAL UPGRADE

EN

Suitability

For all Innopro Paramix CMX and

DCX machines that are suitable

for conversion from "wet-

running" to "quasi dry-running"

vacuum pumps from Gardner

Denver/Elmo Rietschle.

Description

Scope of supply

The standard wet-running vacuum pump used to generate the necessary

 Vacuum pump and modification of

negative pressure (vacuum) for water deaeration is replaced by a quasi dry-

the vacuum piping

running vacuum pump. This almost completely eliminates the continuous

Stainless steel frame

supply of sealing water required to date. In addition, the still remaining

Wiring/piping materials

requirement of manually changing the water of dry-running pumps at regular

 Modification of the automation,

intervals (every 4–8 weeks) can be fully automated.

software and visualization systems

required for operation

 Modification of the machine

Benefit

documentation

 Pneumatically actuated valves

 Tremendous sealing water savings

Software module

 Elimination of the necessity of providing a continuous supply of sealing

Reminder function

water

 Less burden on the wastewater system

Contact

Economic efficiency calculation

fred.burkat@khs.com

Example of a conversion:

Existing Paramix system: Capacity: 43,000 l/hr

Product: CSDs

Continuous water consumption to date: approx. 450 l/hr @ 1,665 m3/year

(230 days of production per year x 16 hrs/day = approx. 3,700 hrs)

Cyclic water consumption after conversion: approx. 150 liters per water change

@ 1.8 m3/year

Water savings: 1,663 m3/year

KHS GmbH

Juchostraße 20

D-44143 Dortmund

* Subject to technical modifications and price changes. On

Deutschland

request, we will be glad to provide you with a binding offer.

Tel: +49.231.569 0

info@khs.com Version 1 Date 29.07.2014