Conversion Catalogue
KHS Innofill
KHS Innofill O+H HANSA AUTOMATIC LEVEL CONTROL - MECHANICALLY OPERATED EN
TECHNICAL UPGRADE
INCREASE IN PRODUCTIVITY
RESOURCE SAVINGS
Suitability
HANSA A filling machine
Scope of supply
Description
Floating unit
The filling level inside the ring tank is monitored by a floating unit and is kept constant by pressure control (venting and counterpressure unit). The set point is adjusted manually with the central slide rod of the counterpressure valve so that the liquid level inside the ring tank can be specifically adjusted to a given product.
Counterpressure valve
Membrane valve
Documentation
Contact
Benefit
Siegfried.Buchholz@KHS.com
Production reliability and reduction of production costs by preventing ring
tank flooding
Conversions time / Delivery time
Uniform product quality through improved filling level precision
Mechanical control unit without additionally required electric components
Duration of on-site installation and commissioning: 2 days or more
KHS Corpoplast GmbH
Meiendorfer Straße 203
22145 Hamburg
Deutschland
Tel: +49.40.67.907 0
info@khs.com
* Subject to technical modifications and price changes. On request, we will be glad to provide you with a binding offer. Version 1 Date 03.04.2014