Conversion Catalogue
KHS Innopro
KHS Innopro O+H INTERMIX CONDUCTIVITY- INDEPENDENT PROBE MEASUREMENT EN
TECHNICAL UPGRADE
INCREASE IN PRODUCTIVITY
RESOURCE SAVINGS
Suitability
INTERMIX C Mixer Requirement: SPS Siemens
Scope of supply
Description
4-5 analog level probes (with
The switching point probes for recording of defined tank levels are exchanged mainly against conductivity-independent, variably operating analog probes. This enables the optimum adaptation of the machine's work flow to the process flows on site. The newly deployed single point switch probes in tanks and pipes are independent from the conductivity of the medium. This results in enhanced and more stable process flows.
connection cable)
6-7 single point switch probes (with
connection cable)
Software extension
KHS Service O+H circuit diagram
update to include new components
Benefit
Contact
Production reliability and reduction of production costs through optimized process adaptation Uniform product quality through stable process flows during production and CIP cleaning
Siegfried.Buchholz@KHS.com
Conversions time / Delivery time
Reduction of CIP operating time , as safety times can be largely dispensed
Duration for on-site installation and commissioning: 3 days and more
Availability of spare parts ensures production reliability
KHS Corpoplast GmbH
Meiendorfer Straße 203
22145 Hamburg
Deutschland
Tel: +49.40.67.907 0
info@khs.com
* Subject to technical modifications and price changes. On request, we will be glad to provide you with a binding offer. Version 1 Date 31.04.2014