Conversion Catalogue
KHS Innofill
KHS Innofill CO²-SAVING AT DRV VF OR VF/N
TECHNICAL UPGRADE
EN
RESOURCE SAVINGS
Suitability
Innofill CO2 savings for filler
types DRV VF and VF/N from
YOM 2006.
Scope of supply
Description
Gas cylinder
Innofill CO2 savings for filler types DRV VF and VF/N from YOM 2006. By
Additional valve cartridges
adding an extra gas cylinder the nozzles to the return gas channel are only
New filling program
opened for slow filling and snifting instead of the nozzles to the return gas
Center valve parts
channel being permanently open, as in the single-chamber system.
Contact
Benefit
Ulrich.Wiedemann@khs.com
As the CO2 nozzles to the return gas channel open and close automatically - as
opposed to the single-chamber filling system - up to 70% of the CO2
previously consumed can be saved.
Economic efficiency calculation
ROI assumptions Filling volume in hectoliters per hour: 625 Price for 1,000 kg
of CO2: €1
60 Savings as opposed to the single-chamber system:
75% CO2 per hour in kg (118 kg instead of 375 kg)
€42 per hour • €336 per eight-hour shift per day
€672 with two shifts per day
€3,360 per week (five days) with two shifts per day
€168,000 per 50 weeks with two shifts per day
KHS GmbH
Juchostraße 20
D-44143 Dortmund
Deutschland
Tel: +49.231.569 0
info@khs.com
* Subject to technical modifications and price changes. On request, we will be glad to provide you with a binding offer. Version 2 Date 17.07.2014