Conversion Catalogue
KHS Innobit
KHS Innobit WIN CC FLEXIBLE WITH RFID PROTECTION
TECHNICAL UPGRADE
EN
Suitability
KHS machines equipped with - Simatic S7 PLC - WinCC Flexible as machine operating system
Scope of supply
Description
RFID reader with IP65 antenna
Supplement for older machines to enable identical login to the visualization as on new KHS machines. Upgrade to enable use of role-based login with RFID tags. Eliminates the necessity of entering user names and passwords to log in and off at the control unit. Login and logoff is carried out by holding the RFID tag in front of the antenna. The user's operating role is stored on his/her tag.
(22.5-mm hole size)
KHS RFID control unit including
pre-parameterized RFID tags with
stored user roles for the machine
Standard function module for the
Benefit
Simatic S7
Modification of the WinCC Flexible
application for use of RFID tags for
Efficient and exact user account management for the machine
user management
Individual rights for different user roles
Wiring for the RFID reader
Avoids operating errors and multi-user accounts
Automatic login by holding the RFID tag in front of the reader
Contact
Automatic logoff by holding the RFID tag in front of the reader again or by a
parameterizable time-out period
Karsten.Vollmer@KHS.com
KHS GmbH
Juchostraße 20
D-44143 Dortmund
Deutschland
Tel: +49.231.569 0
info@khs.com
* Subject to technical modifications and price changes. On request, we will be glad to provide you with a binding offer. Version 1 Date 25.03.2014