Ice Damming Leaks: What Happened?

Many times the problem is partially attributed to the attic insulation being lodged tightly up against the underside of the roof at the soffits, thus prohibiting the proper ventilation of the soffit vents. The lack of soffit baffles, to hold back the insulation and create an air space for the ventilation, greatly diminishes the performance of a balanced roof ventilation system. New roof installations and replacement projects should provide balanced natural draft roof ventilation. As stated previously, ice dams form when a roof has warm upper surfaces and cold lower surfaces, the solution is to equalize temperatures over the entire roof. Heating an entire roof is impractical (and extremely costly), so the most effective solution is to create a cold roof. The most efficient system uses an equal balance of ingress and egress ventilation. Cold outside air is drawn into the soffit vents then it continues up the underside of the roof decking up and out through the ridge vent, dome (button) vents or gable vents. This even distribution of airflow minimizes variations in roof temperatures from the peak to the eaves and reduces the possible occurrence of ice damming. Another line of defense against infiltrating water is the proper installation of an ice and water shield or an equivalent waterproofing membrane and drip edge installation. Ice and water shield must project a minimum twenty-four (24”) inches past the interior face of the exterior wall to meet the building code requirements. The issue of proper ventilation and ice shields at the eave is not an option that the association may choose to comply with. They are code requirements. The issue of adequate ventilation is also a requirement of all shingle manufacturers to comply with warranty issues. If the association opts not to install adequate ventilation with a new roof, they are in effect voiding the warranty of the new shingles (typically a 20 to 30 year warranty).

Installing drip edges at the eaves and rakes and installing a continuous run of ice shield along the step walls, low slope roof areas and other vulnerable locations will greatly reduce possibilities of leaks. When drip edge is installed correctly, it can also act to protect the eaves from water infiltration. Additional ice shields prevent water from penetrating back into the building envelope even when ice damming does exist. Your roof replacement project should include these very important aspects to ensure that quality results are achieved and ice damming potential is minimized. Attention to detail in the installation of all flashings and roofing components also has a significant effect to the performance of the roof system under these extreme conditions. Completely eliminating any possibility of damage resulting from ice damming is difficult while remaining within standard building codes and practices; however, even under severe conditions, if your roof has been engineered and installed with care and in accordance with the building codes, the chance of damage should be greatly reduced.

2

www.falconengineering.com

Made with FlippingBook HTML5