ESTRO 2020 Abstract book

S460 ESTRO 2020

[3] Matter M, et al. Phys Med Biol 2018 [4] Meijers A, et al. Med Phys 2019 [5] Scandurra D, et al. Phys Med Biol 2016 [6] Belosi MF, et al Radiother Oncol 2017 [7] Winterhalter C, et al Phys Med Biol 2019 [8] Toscano S, et al. Phys Med Biol 2019 SP-0747 What log file based QA can do and what it cannot solve M. Pasler 1 1 Lake Constance Radiation Oncology Center, Department for Medical Physics, Friedrichshafen, Germany Abstract text Log files provide versatile applications as complementary methods to typical QA measurements, especially with regard to complex and adaptive radiotherapy techniques. For most radiotherapy treatment units, log files are freely accessible, for others however, log file access is limited. Studies reporting on log file applications are therefore unevenly published, depending on access to log file data. In-house developed software tools or commercially available products process and evaluate log files for multiple purposes including data transfer testing, visualising dynamic parameters, localizing machine malfunctions, machine performance monitoring, inter- institutional comparison, prediction of treatment plan deliverability/ robustness and dose recalculation. However, log files cannot replace every component of the dosimetric and technical QA chain: for instance, log file evaluation does not provide any check on aspects such as TPS beam modelling issues, absolute dose output calibration, patient changes during treatment or IGRT issues. Moreover, log files are generated by the delivery system and rely on feedback data from the linac and hence they are not strictly an independent measure. This presentation gives an overview of the potentials and limitations of log file analysis with a focus on state-of-the- art linear accelerators. SP-0748 The worst-case scenario survival guide: uncertainties in proton therapy. M. Lowe 1 1 The Christie NHS Foundation Trust, CMPE, Manchester, United Kingdom Abstract text The finite range and sharp distal dose fall-off of proton beams can confer an advantage compared to photons when it comes to producing dose distributions within a patient but these same properties make proton plans more sensitive to various uncertainties. This talk will address the main sources of uncertainty in proton therapy and their effects on the delivered dose distribution. We will look at how plans can be evaluated in the face of uncertainty and what we should look at when what we are used to seeing on screen in the treatment planning system may be unreliable. We will discuss what can be done to mitigate the effects of inevitable uncertainties, what should be anticipated upfront and whether it is always worth the cost of being robust to uncertainty. Symposium: PBT planning: lessons learned

Symposium: Quo-vadis log file based QA for adaptive radiotherapy?

SP-0745 Log file based QA in practice – photon beam therapy N. Papanikolaou 1 , C. Kabat 1 1 mays Cancer Center - Ut Health San Antonio- Md Anderson Cancer Center, Medical Physics, San Antonio, Usa Abstract text Modern linear accelerators produce a log file anytime they are in operation. Those files document numerous parameters that are recorded during the radiation delivery and can provide valuable feedback on machine performance. Machine log files can also be used as a means to develop a quality control program for a linear accelerator. The information contained within the machine’s log file can help us evaluate the quality of the delivery of a specific patient’s treatment, while large sets of log files can provide insight on radiation delivery accuracy and consistency over time. In this presentation, we will discuss the basic structure of the data found within the log files and how one can interpret them. We will then discuss the pros and cons of using log files in a QA program. Finally, we will present a log file based analysis that can be used to automate record-based delivery checks between the treatment planning system, the record-verify system and the linac. Those checks can be done for every patient and every fraction. Learning Objectives: -Understand the data found in Log Files -Review of log file data evaluation methodologies -Provide an overview of the log file-based QA process including its benefits and potential challenges SP-0746 Log file based QA in practice – proton beam therapy F. Albertini 1 1 Paul Scherrer Institute PSI, Center for Proton Therapy CPT, Villigen PSI, Switzerland Abstract text The clinical standard for patient specific quality assurance (PSQA) in proton therapy still consists in time- intensive measurement of the planned dose distribution. Additionally, these measurements do not consider the influence of density heterogeneities in the patient and are insensitive to daily delivery errors. In the last years it has been proposed to use the measured beam parameters, recorded during the delivery in log-files , to reconstruct the delivered dose in the patient [1–8]. This approach has been suggested to be a faster alternative to the standard PSQA. In this talk, a review of the current literature will be presented. Besides, it will be shown that the log-file based QA is not only a valid strategy but also that it is more sensitive to detect delivery errors (e.g. unplanned systematic shift of the Bragg peak position) than the PSQA based on measurements. Additionally, it will be shown that by reconstructing the dose with a Monte Carlo algorithm is the most accurate way to verify the daily delivered dose in the patient anatomy. With this approach indeed both calculational and delivery errors are considered.

[1] Meier G, et al Phys Med Biol 2015 [2] Zhu X, et al. Cancers (Basel) 2015

Made with FlippingBook - Online magazine maker