Special Features

STC-MSC EXIST BLDG by CHIEF at ROOF CAP detail 2

1/4-14 X 7/8" WT FASTENERS

TAPE MASTIC

SIKA 511 (1/4" TO 5/16" BEADS)

ROOF CAP

ROOF CAP

SIKA 511 (1/4" TO 5/16" BEADS)

ROOF CAP

1/2"

3"

REMOVE LOCK FORM AT SPLICE

1/4-14 X 7/8" WT FASTENERS

TAPE MASTIC

5"

STEP 1: Install roof cap up to the point that sliding joint is to be located.

STEP 2: Install (2) runs of sika 511 across trim profile. Locate as dimensioned.

STEP 3: Lap next roof cap piece onto previous piece 5". Do not install fasteners in the sliding trim.

SLIDING TRIM ROOF CAP LAP