Archive 2018 International Catalog

Selection tables A7 UNITRONIC ® BUS and ETHERLINE ® – technical data

ÖLFLEX ® ACCESSORIES FLEXIMARK ® SILVYN ® SKINTOP ® EPIC ® HITRONIC ® ETHERLINE ® UNITRONIC ® APPENDIX

Usage criteria

Cable designation

Page 429

429

429

429

420

435

444

444

449

A

A

A + TORSION P Cat.6

A FRNC FC +

A P FC +

A Y FC +

A Y FLEX FC

A FRNC FLEX FC

A + TORSION Y Cat.6

ETHERLINE ® PN Cat.5e Y

ETHERLINE ® TRAY ER PN Y FC

ETHERLINE ® Cat.5e YY

ETHERLINE ® FD P Cat.5e

ETHERLINE ® FD P FC Cat.5

highly flexible application ETHERLINE ® PN Cat.6 ETHERLINE ® PN Cat.7 FRNC ETHERLINE ® PN Cat.6

ETHERLINE ® PN Cat.7 P

ETHERLINE ® PN Cat.6

ETHERLINE ® PN + Cat.7 Y

ETHERLINE ® PN Cat.6

ETHERLINE ® PN Cat.6

ETHERLINE ® FD Cat.6

ETHERLINE ® TORSION Cat.7

ETHERLINE ® Y FC Cat.5

ETHERLINE ® FD P Cat.6

Parameter Characteristic impedance Ω

100 100 100 100 100 100 100 100 100 100 100 100 100 100

Mutual capacitance (800 Hz) max. nF/km

48 48 48 48 50 52

50

Peak operating voltage V (not for power applications)

125 125 125 125 125 125 125 125 125 125 125 125 125 125

Test voltage, core/core, U eff V

1000 2000 1000 1000 1000 700 1000 1000 1000 1000 1000 1000 1000 750

Conductor resistance (loop) Data network cable pair max. Ω/km

118 115 115 118 290 120 118 118 118 143 143 175 175 175

Minimum bending radius, fixed installation

7.5 x D 10 x D 10 x D 4 x D 8 x D 5 x D 4 x D 4 x D 4 x D 8 x D 8 x D 8 x D 8 x D 8 x D

Minimum bending radius, flexing

15 x D 15 x D 15 x D 8 x D 15 x D 8 x D 8 x D 8 x D 8 x D 15 x D 15 x D 15 x D 15 x D 15 x D

Temperature range fixed installation

from °C

- 40 +70 - 5 +50

- 40 +80 - 20 +60

- 40 +80 - 20 +60

- 25 +80 - 5 +70

- 30 +80 - 5 +70

- 30 +70

- 25 +80

- 40 +80

- 30 +80

- 10 +70 - 10 +70

- 25 +80 - 25 +80

- 40 +80 - 10 +70

- 40 +80 - 30 +70

- 40 +80 - 30 +70

to °C

Temperature range

from °C

- 20 +60 –

flexing

to °C

Usage criteria

Cable designation

Page 328

328

329

329

329

328

361

361

361

361

378

378

378

UNITRONIC ® BUS ASI (G) yellow + black fixed installation/flexible

UNITRONIC ® BUS ASI (TPE) yellow + black fixed installation/flexible UNITRONIC ® BUS ASI LD FD P yellow + black

highly flexible application UNITRONIC ® BUS ASI FD (TPE) A yellow + black

highly flexible application UNITRONIC ® BUS ASI FD P FRNC yellow + black fixed installation

UNITRONIC ® BUS ASI (PVC) A yellow + black

fixed installation UNITRONIC ® DeviceNet

THICK + THIN (halogen-free) fixed installation UNITRONIC ® DeviceNet THICK + THIN (PVC) fixed installation UNITRONIC ® DeviceNet

THICK + THIN (PUR) highly flexible UNITRONIC ® DeviceNet

THICK + THIN (PVC) highly flexible UNITRONIC ® BUS SAFTEY

fixed installation/highly flexible UNITRONIC ® BUS EIB fixed installation UNITRONIC ® BUS EIB COMBI fixed installation

Parameter Characteristic impedance Ω

120 120 120 120 100-

200 –

max. 100

Mutual capacitance (800 Hz) max. nF/km

– 39.8 39.8 39.8 39.8 45 max. 100

Peak operating voltage V (not for power applications)

300 300 300 300 300 300 300 300 300 300 250 250 250

Test voltage, core/core, U eff V

2000 2000 2000 2000 2000 2000 2000 2000 2000 2000 3000 4000 4000

Conductor resistance (loop) Data network cable pair max. Ω/km

max. 130

27.4 27.4 16.5 27.4 27.4 27.4 THICK 45 THIN 180

THICK 45 THIN 180

THICK 45 THIN 180

THICK 45 THIN 180

52 max. 130

Minimum bending radius, fixed installation

3 x D 3 x D 3 x D 3 x D 3 x D 3 x D 10 x D 10 x D –

– 8 x D 10 x D 10 x D

Minimum bending radius, flexing

– 6 x D 6 x D –

– 10 x D 10 x D –

Temperature range fixed installation

from °C

- 40 +85

- 40 +85

- 40 +80 - 30 +70

- 40 +105 - 30 +105

- 40 +80

- 30 +90

- 25 +80

- 20 +80 –

- 40 +80

- 30 +70

- 30 +70

to °C

Temperature range

from °C

- 30 +70 –

- 40 +80

- 10 +80

- 30 +80 –

flexing

to °C –

For current information see: www.lappgroup.com

1081

Made with FlippingBook - professional solution for displaying marketing and sales documents online