Archive 2018 International Catalog
Selection tables A7 UNITRONIC ® BUS and ETHERLINE ® – technical data
ÖLFLEX ® ACCESSORIES FLEXIMARK ® SILVYN ® SKINTOP ® EPIC ® HITRONIC ® ETHERLINE ® UNITRONIC ® APPENDIX
Usage criteria
Cable designation
Page 429
429
429
429
420
435
444
444
449
A
A
A + TORSION P Cat.6
A FRNC FC +
A P FC +
A Y FC +
A Y FLEX FC
A FRNC FLEX FC
A + TORSION Y Cat.6
ETHERLINE ® PN Cat.5e Y
ETHERLINE ® TRAY ER PN Y FC
ETHERLINE ® Cat.5e YY
ETHERLINE ® FD P Cat.5e
ETHERLINE ® FD P FC Cat.5
highly flexible application ETHERLINE ® PN Cat.6 ETHERLINE ® PN Cat.7 FRNC ETHERLINE ® PN Cat.6
ETHERLINE ® PN Cat.7 P
ETHERLINE ® PN Cat.6
ETHERLINE ® PN + Cat.7 Y
ETHERLINE ® PN Cat.6
ETHERLINE ® PN Cat.6
ETHERLINE ® FD Cat.6
ETHERLINE ® TORSION Cat.7
ETHERLINE ® Y FC Cat.5
ETHERLINE ® FD P Cat.6
Parameter Characteristic impedance Ω
100 100 100 100 100 100 100 100 100 100 100 100 100 100
Mutual capacitance (800 Hz) max. nF/km
48 48 48 48 50 52
–
–
–
–
–
–
–
50
Peak operating voltage V (not for power applications)
125 125 125 125 125 125 125 125 125 125 125 125 125 125
Test voltage, core/core, U eff V
1000 2000 1000 1000 1000 700 1000 1000 1000 1000 1000 1000 1000 750
Conductor resistance (loop) Data network cable pair max. Ω/km
118 115 115 118 290 120 118 118 118 143 143 175 175 175
Minimum bending radius, fixed installation
7.5 x D 10 x D 10 x D 4 x D 8 x D 5 x D 4 x D 4 x D 4 x D 8 x D 8 x D 8 x D 8 x D 8 x D
Minimum bending radius, flexing
15 x D 15 x D 15 x D 8 x D 15 x D 8 x D 8 x D 8 x D 8 x D 15 x D 15 x D 15 x D 15 x D 15 x D
Temperature range fixed installation
from °C
- 40 +70 - 5 +50
- 40 +80 - 20 +60
- 40 +80 - 20 +60
- 25 +80 - 5 +70
- 30 +80 - 5 +70
- 30 +70
- 25 +80
- 40 +80
- 30 +80
- 10 +70 - 10 +70
- 25 +80 - 25 +80
- 40 +80 - 10 +70
- 40 +80 - 30 +70
- 40 +80 - 30 +70
to °C
Temperature range
from °C
- 20 +60 –
–
–
flexing
to °C
Usage criteria
Cable designation
Page 328
328
329
329
329
328
361
361
361
361
378
378
378
UNITRONIC ® BUS ASI (G) yellow + black fixed installation/flexible
UNITRONIC ® BUS ASI (TPE) yellow + black fixed installation/flexible UNITRONIC ® BUS ASI LD FD P yellow + black
highly flexible application UNITRONIC ® BUS ASI FD (TPE) A yellow + black
highly flexible application UNITRONIC ® BUS ASI FD P FRNC yellow + black fixed installation
UNITRONIC ® BUS ASI (PVC) A yellow + black
fixed installation UNITRONIC ® DeviceNet
THICK + THIN (halogen-free) fixed installation UNITRONIC ® DeviceNet THICK + THIN (PVC) fixed installation UNITRONIC ® DeviceNet
THICK + THIN (PUR) highly flexible UNITRONIC ® DeviceNet
THICK + THIN (PVC) highly flexible UNITRONIC ® BUS SAFTEY
fixed installation/highly flexible UNITRONIC ® BUS EIB fixed installation UNITRONIC ® BUS EIB COMBI fixed installation
Parameter Characteristic impedance Ω
–
–
–
–
–
–
120 120 120 120 100-
–
200 –
max. 100
Mutual capacitance (800 Hz) max. nF/km
–
–
–
–
–
– 39.8 39.8 39.8 39.8 45 max. 100
Peak operating voltage V (not for power applications)
300 300 300 300 300 300 300 300 300 300 250 250 250
Test voltage, core/core, U eff V
2000 2000 2000 2000 2000 2000 2000 2000 2000 2000 3000 4000 4000
Conductor resistance (loop) Data network cable pair max. Ω/km
max. 130
27.4 27.4 16.5 27.4 27.4 27.4 THICK 45 THIN 180
THICK 45 THIN 180
THICK 45 THIN 180
THICK 45 THIN 180
52 max. 130
Minimum bending radius, fixed installation
3 x D 3 x D 3 x D 3 x D 3 x D 3 x D 10 x D 10 x D –
– 8 x D 10 x D 10 x D
Minimum bending radius, flexing
–
– 6 x D 6 x D –
–
–
– 10 x D 10 x D –
–
–
Temperature range fixed installation
from °C
- 40 +85
- 40 +85
- 40 +80 - 30 +70
- 40 +105 - 30 +105
- 40 +80
- 30 +90
- 25 +80
- 20 +80 –
- 40 +80
- 30 +70
- 30 +70
–
to °C
Temperature range
from °C
- 30 +70 –
- 40 +80
- 10 +80
- 30 +80 –
–
–
–
–
flexing
to °C –
For current information see: www.lappgroup.com
1081
Made with FlippingBook - professional solution for displaying marketing and sales documents online