Engineered Solutions of Georgia
Fortress Strap Spacing Calculator
Customer Name: Property Address: City:
Brenda Ridl 5312 Lake Springd Drive Dunwoody
State: Ga
Zip: 30338
Wall location
Front and Rear Foundation Wall
Height of wall (ft): 8 Location of crack above the floor (ft): 7
Type of construction: Size of Masonry Block: Concrete wall thickness (in):
Masonry Block 12
Wall thickness (in)
11.625
Allowable strength of wall (psi)
1500
Width of CFRP strips (in)
6
Soil Pressure (pcf)
45
Total force against wall (plf)
1440 M(max) (ft-lb per ft) 1478.0167
Location of M(max) from bottom (ft) 3.3811978 Equivalent uniform load (plf per ft)) 184.75209 Force location from bottom (ft) 2.6666667 Reaction at top of wall (plf) 480 Reaction at bottom of wall (plf) 960 Moment at crack location (in-lb/ft) 5670 Tension on the inside face of wall (plf) 487.74194 Adhesive area required (sqin/ft) 8.3956284
Spacing based on area above crack (ft) Spacing based on area below crack (ft)
8.58
60.03
MAX ALLOWABLE SPACING 5.00 feet
Made with FlippingBook Learn more on our blog