Connectivity Guide

for RS-485/RS-422 bus systems; stationary applications; 100–120 Ω UNITRONIC ® BUS LD

Cable tray Control board Motors, drives & chain Robot base Main control box Power outlet Robot arm ot r , in ai o l x l t Part Number 2170803 2170204 2170205

OR-00

FR-01

FL-02

MP-01

Construction

Conductors: Stranded bare copper Insulation: Polyethylene Shielding: Copper braid Jacket: PVC; violet

Technical Data

Minimum Bend Radius:

8 x cable diameter

Temperature Range:

-40°C to 80°C

Nominal Voltage:

250V (not for power applications)

Characteristic Impedance:

100–120 Ω

Nominal Capacitance:

18 pF/ft (800 Hz)

Color Code:

2 :

3 :

1:

Approvals:

see table for individual approvals

UL:

CMX

Canada:

CSA CMX

Additional:

RoHS

Nominal Outer Diameter

Copper Weight

Approx. Weight

SKINTOP ® MS-SC PG thread

Number of Pairs

Approvals

in

mm lb/mft

lb/mft

24 AWG (0.25 mm²) 2170203 1

0.225 5.7

12 12 25 25

25 53112210 26 53112210 48 53112210 48 53112210

1 2 3

UL/CSA CMX 0.225 5.7

— —

0.280 7.1 0.284 7.2

If not otherwise specified, all values relating to the product are nominal values. Photographs are not to scale and are not true representations of the products in question.