2017 Section 7 Green Book

Otolaryngology–Head and Neck Surgery 154(3)

0.75 (0.43 - 0.95) 1.00 (0.48 - 1.00) 1.00 (0.54 - 1.00) 0.87 (0.60 - 0.98) 0.91 (0.59 - 1.00) 0.50 (0.16 - 0.84) 0.83 (0.52 - 0.98) 1.00 (0.40 - 1.00) 1.00 (0.40 - 1.00) 0.91 (0.71 - 0.99) 1.00 (0.29 - 1.00) 0.70 (0.35 - 0.93) 1.00 (0.59 - 1.00) 0.75 (0.48 - 0.93) 0.88 (0.47 - 1.00) 1.00 (0.03 - 1.00) 1.00 (0.72 - 1.00) 1.00 (0.40 - 1.00) Sensitivity (95% CI)

Ceulemans Chaiken Conessa Fakhry Goerres Kishino Kitagawa McCollum Moeller Li Gupta Kim

Mori

Ng

Rege Sjovall Wang

Yen

Pooled Sensitivity = 0.86 (0.80 to 0.91) Chi-square = 24.30; df = 17 (p = 0.1114) Inconsistency (I-square) = 30.1 %

0

0.2

0.4

0.6 0.8

1

Sensitivity

0.79 (0.59 - 0.92) 0.78 (0.40 - 0.97) 0.81 (0.64 - 0.92) 0.83 (0.69 - 0.92) 0.93 (0.68 - 1.00) 0.92 (0.80 - 0.98) 0.92 (0.84 - 0.97) 0.32 (0.14 - 0.55) 0.89 (0.67 - 0.99) 0.86 (0.64 - 0.97) 0.65 (0.43 - 0.84) 0.94 (0.86 - 0.98) 0.40 (0.27 - 0.53) 0.98 (0.91 - 1.00) 0.86 (0.42 - 1.00) 0.78 (0.66 - 0.87) 0.91 (0.76 - 0.98) 1.00 (0.90 - 1.00) Specificity (95% CI)

Ceulemans Chaiken Conessa Fakhry Goerres Kishino Kitagawa McCollum Moeller Li Gupta Kim

Mori

Ng

Rege Sjovall Wang

Yen

Figure 4. Forest plots of sensitivity and specificity for positron emission tomography and positron emission tomography/computed tomography in the diagnosis of residual and/or recurrent disease at the neck nodes.

Pooled Specificity = 0.82 (0.79 to 0.85) Chi-square = 138.99; df = 17 (p = 0.0000) Inconsistency (I-square) = 87.8 %

0

0.2

0.4

0.6 0.8

1

Specificity

Figure 2. Forest plots of sensitivity and specificity for positron emission tomography and positron emission tomography/computed tomography in the diagnosis of residual and/or recurrent disease at the primary site.

Sensitivity

SROC Curve

Sensitivity

SROC Curve

1

1

Symmetric SROC AUC = 0.8644 SE(AUC) = 0.0445 Q* = 0.7950 SE(Q*)= 0.0433

Symmetric SROC AUC = 0.9149 SE(AUC) = 0.0162 Q* = 0.8475 SE(Q*)= 0.0183

0.9

0.9

0.8

0.8

0.7

0.7

0.6

0.6

0.5

0.5

0.4

0.4

0.3

0.3

0.2

0.2

0.1

0.1

0

0

0

0.2

0.4

0.6

0.8

1

0

0.2

0.4

0.6

0.8

1

1-specificity

1-specificity

Figure 3. Summary receiver-operating characteristic curves for positron emission tomography and positron emission tomography/ computed tomography in the diagnosis of residual and/or recurrent disease at the primary site.

Figure 5. Summary receiver-operating characteristic curves for positron emission tomography and positron emission tomography/ computed tomography in the diagnosis of residual and/or recurrent disease at the neck nodes.