GE Aftermarket Catalog

Low Voltage Power and DC Circuit Breakers EntelliGuard ® TU Trip Unit Conversion Kits Selection Guide

Adv. Options

Model C = Generation

Sensor Ratings

Trip Functions

= = =

= LSI 2 = LSIG 2 = LSIGDA

= 01 = 02 = 04 = 06 = 08 = 16 = 20 = 30 = 32 = 40 = XA = XC = XE = XF = XG = XI = XJ

A B C

Ammeter

150A 225A 400A 600A 800A

04 05 09 11 12

Ammeter + RELT 24

Advanced Metering, Relaying, Waveform Capture, Modbus Comm, RELT 24

LSH 2

= =

LSHG 2

Wiring

1600A 2000A 3000A 3200A 8 4000A

3 Wire = 3 4 Wire 6 = 4

ZSI – Instantaneous is available. Contact factory. RELT (Reduced Energy Let Through) – Order RELT Switch Kit GTURSK separately

Switchgear 2

Trip Unit Functions

=

LSI

Long Time, Short Time (Switchable), & Instantaneous (Switchable)

150A No CTs 7 400A No CTs 7 800A No CTs 7 1600A No CTs 7 2000A No CTs 7 3200A No CTs 7,8 4000A No CTs 7

= =

LSIG

LSI & Ground Fault Trip

Sensor Type

LSIGDA

LSIG with Switchable Ground Fault Alarm (not UL Listed)

F = Fixed CTs

=

LSH

Long Time, Short Time (Switchable), High Range Instantaneous (Non-Switchable) Up to 22KA (AKR30S Only) 2

=

LSHG

LSH & Ground Fault Trip (AKR30S Only) 2

1 For converting AK-2 version breakers and newer, not applicable for AK-1 or AKR. 2 AKR30S Instantaneous Is Non-Switchable and the Non-Switchable High Range Instantaneous max is 22KA. LSH and LSHG Are Only Available on AKR30S. 3 Breakers equipped with older style open fuse lockout devices (OFLO), must be retrofitted with newer style OFLO device prior to conversion process. Order replacement OFLO kits as follows: AKU-50 - order OFLO Kit #121C2870G2, AK-75 - order OFLO kit #121C2870G3, AK-100 - order OFLO kit #121C2870G4. 4 Not applicable for converting breakers equipped with Power Sensor - contact factory. 5 Contact the factory for stationary breaker applications. 6 Only applicable to trip units with ground fault. 7 Available only for MicroVersaTrip RMS-9 type AKR breakers equipped with fixed current sensors. 8 Not available on AK-75 breaker frames. 9 Contact factory for availability. 10 Not applicable for slate version breakers. 15 Order for red or black insulator as applicable. 16 Not applicable to fixed mounted breakers. 17 Only applicable for blue-gray color version breakers. 18 Applicable to both “A” and “B” version breakers. 19 Applicable to both nameplated versions of integral fused breakers (i.e., LA-600F and LAF-600). 20 Only applicable for gold color version breakers. 21 800-amp version of the LA-50 breaker. 22 Only applicable for the 1600-amp, 6-pole primary disconnect version of the LA-50 breaker. 23 Only applicable for 1600-amp, 12 pole primary disconnect version of the LA-50 breaker. 24 Requires 24VDC control power. 25 Existing Allis-Chalmers, I-T-E and Westinghouse bell alarms will not work with EntelliGuard TU.. 11 Left pole accessories must be removed or relocated. 12 Right pole accessories must be removed or relocated. 13 1600-amp version of the KC breaker. 14 800-amp version of the KC breaker.

Kits Without Sensors For kits ordered without sensors, deduct $200.00 from the list price of the kit with sensors. Please refer to the sensor rating column above for the appropriate “X” sensor code. Zone Selective Interlock For Zone Selective Interlock (ZSI) Short Time, Ground Fault and Instantaneous, add $550.00 to the list price. (Also requires purchase of ZSI module TIM1 [120 VAC control voltage], list price $402.00, GO-245B .)

Reference Publications EntelliGuard ® TU Conversion Kit Brochure

DET-722 DEH-3456 DEH-4567 DEH-4568A GEH-6466 DEH-40027 GEH-5967 GEH-5966 GEH-5965 GEH-5964 GEH-6318 GEH-6319 DEH-023 GEH-6320 GEH-6294 GEH-6433 GEH-6293 GEH-6295 DEH-133 DEH-40019 DEH-40008

EntelliGuard ® TU Conversion Kit Supplemental Instructions EntelliGuard ® TU Trip Unit Installation/Instruction Manual

EntelliGuard ® TU Test Set - GTUTK20

GE AK-1-15, AK-1-25

GE AK-1-50

GE AK-15, AK, AKU-25, AKR-30S, AKRU-30S GE AKR-30,30H, AKRU-30, AKR-50, AKJ-50 Series

GE AK-100, AK,U,T,S,SU,ST-50, AK-75 GE AKR-100, AKR-75, AKW-100

Westinghouse DB-15

Westinghouse DB-25, DBL-25 (225A), DB-50, DBL-50

Westinghouse DS-206, DSL-206, DS416, DSL-416, DS-420, DS-632

Westinghouse DB-100 (4000A), DB-75 (3000A)

ITE K-1600 (red), K, KDON-1600 Black, K-2000, K-225, K-600, KDON-600, K-800, KDON-800, KDON-1600 (red)

ITE KC (1600A), KC (800A)

ITE KA

ITE KB (Metal), KB (Slate Drawout), KB (Slate Fixed)

ITE K-3000, K-4000 ITE KD-3000, KE-4000

Allis Chalmers LA, LAF - 1600 (BLUE), LA, LAF-600 (BLUE)

Allis Chalmers LA, LAF - 1600 (GOLD), LA, LAF-600 (GOLD), LA, LAF-800, RL, RLX, RLE-1600 & 800

DEH-40009A

Note: Conversion Kit Pricing tables are located on pages 2-14 through 2-16.

Aftermarket Catalog

www.geelectrical.com

2-13