SLV Lighting

ICONS

575

PRODUCT FEATURES

APPLICATION / INSTALLATION

Mounting space · Wall [with respective accessories] · Ceiling · Floor · Recessed

Operation voltage · High-voltage 120VAC · Integrated converter for 120V alternating voltage to 350mA direct current · Low-voltage with voltage converter for high-voltage systems 120VAC/12VDC · Low-voltage 12VDC

120VAC

120VAC

350 mA

12VDC 120VAC

12VDC

· Mounting surface on the wide side · Mounting surface on the small side [vertical] · Mounting surface on the small side [horizontal]

Fittings with built-in LEDs LED cannot be changed in the luminaire.

· Application exclusively indoors

Lamp suitable for application in fittings without protective glass.

LED can be replaced with the help of additional tools.

Cable diameter in inches

Dimmable

7–12

Through-wiring … · possible. · possible up to the indicated number of fittings.

LED 35 pcs.

Module 1 COB LED

LED equipment Number and type of built-in LEDs.

max.10

Weight of the product in lbs

Independent converter [Electronic transformer for application outside of fittings as well.]

9.5

Adjustability: Fitting · Slewing range · Pivoting range

180°

Specification of ETL listing Dry / Damp / Wet

340°

Adjustability: Lamp/part of fitting · multi-directional · multi-directional up to the indicated value

60°

50° 15°–30°

Beam angle symmetrical / focusable / asymmetrical

Pendant cable length for pendants in ft

1.5 ft

Maximum distance between wires for low-voltage wire systems in inches

20

Average life span of a lamp or fitting in hours.

2500

[For fittings with integrated LED lamps: Average life span of the whole product in hours.]

We are happy to provide you with a light distribution curve for the respective product on request.

Reflector lamps | Multi mirror lamps [cool beam]: The main heat is emitted towards the back side of the reflector. Reduced thermal load at the light beam. Reflector lamps | Direct beam lamps [no cool beam]: Thermal load at the light beam, therefore hardly any heat development on the back side of the reflector.

SPEZIFIC DATA – RECESSED FITTINGS

SAFETY-RELATED INFORMATION

Installation depth in inches [In case an installation box is included, the dimensions refer to its size.]

16A max.

Maximum current carrying capacity

9.5

Thermal fuse with temperature indication in °F

Installation cutout in inches Shape and size

115°F

9.5/22 9.5/22 7.2

90°F

· Allowed surrounding temperature in °F · Allowed temperature range in °F

Heat development on the inground fitting’s surface

ta -25°–+40°

ta 40°

0.8 t

Weight capacity of the product up to the indicated value in tons. Measures are based on installation in concrete.

Lamp is equipped with UV protection .

Impact resistance of the product up to the indicated value in Joule

5 J