SLV Lighting
ICONS
575
PRODUCT FEATURES
APPLICATION / INSTALLATION
Mounting space · Wall [with respective accessories] · Ceiling · Floor · Recessed
Operation voltage · High-voltage 120VAC · Integrated converter for 120V alternating voltage to 350mA direct current · Low-voltage with voltage converter for high-voltage systems 120VAC/12VDC · Low-voltage 12VDC
120VAC
120VAC
350 mA
12VDC 120VAC
12VDC
· Mounting surface on the wide side · Mounting surface on the small side [vertical] · Mounting surface on the small side [horizontal]
Fittings with built-in LEDs LED cannot be changed in the luminaire.
· Application exclusively indoors
Lamp suitable for application in fittings without protective glass.
LED can be replaced with the help of additional tools.
Cable diameter in inches
Dimmable
7–12
Through-wiring … · possible. · possible up to the indicated number of fittings.
LED 35 pcs.
Module 1 COB LED
LED equipment Number and type of built-in LEDs.
max.10
Weight of the product in lbs
Independent converter [Electronic transformer for application outside of fittings as well.]
9.5
Adjustability: Fitting · Slewing range · Pivoting range
180°
Specification of ETL listing Dry / Damp / Wet
340°
Adjustability: Lamp/part of fitting · multi-directional · multi-directional up to the indicated value
60°
50° 15°–30°
Beam angle symmetrical / focusable / asymmetrical
Pendant cable length for pendants in ft
1.5 ft
Maximum distance between wires for low-voltage wire systems in inches
20
Average life span of a lamp or fitting in hours.
2500
[For fittings with integrated LED lamps: Average life span of the whole product in hours.]
We are happy to provide you with a light distribution curve for the respective product on request.
Reflector lamps | Multi mirror lamps [cool beam]: The main heat is emitted towards the back side of the reflector. Reduced thermal load at the light beam. Reflector lamps | Direct beam lamps [no cool beam]: Thermal load at the light beam, therefore hardly any heat development on the back side of the reflector.
SPEZIFIC DATA – RECESSED FITTINGS
SAFETY-RELATED INFORMATION
Installation depth in inches [In case an installation box is included, the dimensions refer to its size.]
16A max.
Maximum current carrying capacity
9.5
Thermal fuse with temperature indication in °F
Installation cutout in inches Shape and size
115°F
9.5/22 9.5/22 7.2
90°F
· Allowed surrounding temperature in °F · Allowed temperature range in °F
Heat development on the inground fitting’s surface
ta -25°–+40°
ta 40°
0.8 t
Weight capacity of the product up to the indicated value in tons. Measures are based on installation in concrete.
Lamp is equipped with UV protection .
Impact resistance of the product up to the indicated value in Joule
5 J