Overhead Deadends (DA) - Distribution Connectors
DEADENDS BOLTED QUADRANT STRAIN CLAMP FERROUS
DA 21
DUCTILE IRON SWDE/MD
For deadending static wires.
May be used to deadend copper or Copperweld ® phase conductors. Magnetic induction heating will occur.
Material:
Body and Keeper — Galvanized Ductile Iron Sockets and Clevises — Ductile Iron, Galvanized Cotter Pin — #302 Stainless Steel
DIMENSIONS INCHES (MM)
CATALOG NUMBER
L
H
C
W
MD52N MD52S MD52C
2-25/32 (70.61)
4-3/32 (103.89)
2-1/8 (54.10)
5/8 (15.88)
SWDE46N SWDE46S SWDE46C SWDE55N SWDE55S SWDE55C SWDE84N SWDE84S SWDE84C
6 (152.40)
5-1/2 (139.70)
4-3/8 (111.12)
5/8 (15.88)
8 (203.20)
8-5/8 (219.08)
7-3/8 (187.33)
11/16 (17.46)
10-3/4 (273.05)
10-5/8 (270.00)
8-7/16 (214.38)
15/16 (23.88)
Product Data & Conductor Size
CLAMPING RANGE
FITTING
GALV. STEEL
U-BOLTS
ULTIMATE BODY STRENGTH LBS. (KG)
SIZE INCHES (MM)
APPROX. WT. EACH LBS. (KG) 1.9 (.86) 3.2 (1.45) 3.5 (1.59) 4.1 (1.86) 5.4 (2.45) 5.7 (2.49)
CATALOG NUMBER
CAT. NO.
FIGURE NUMBER
NO. STR. GRADE
INCHES (MM)
TYPE None Socket Clevis None Socket Clevis
DIA.
COPPER
NO.
MD52N MD52S MD52C
-- SA04 CA04 -- SA04 CA04
ACSR #6 (6/1) to 4/0 (6/1) 3/8 (9.53) 7/16 (11.11) 3/16 (4.76) 1/4 (6.35) 9/32 (7.14) 5/16 (7.94) 3/8 (9.53) 7/16 (11.11) 1/2 (12.70) 3/8 (9.53) thru 3/4 (19.05)
#6 Sol. To 4/0 Str. #6 Str. To 4/0 Sol.
.160-.563 (4.06-14.30)
1/2 (12.70)
4
— —
12,000 (5,443)
1
SWDE46N SWDE46S SWDE46C
7 7 7
Utilities High Str. Utilities All Grades Within Clamping And Strength Rating
15,000 (6,804) 15,000 (6,804) 15,000 (6,804)
.18-.46 (4.57-11.68)
1/2 (12.70)
1
2
SWDE55N SWDE55S SWDE55C
None Socket Clevis
-- SA04 CA04
7 7 7
#4 (7) To 4/0 (19)
19,000 (8,618) 18,000 (8,165) 18,000 (8,165)
6.0 (3.08) 8.0 (3.63) 8.4 (3.81)
.22-.55 (5.59-13.97)
1/2 (12.70)
2
3
SWDE84N SWDE84S SWDE84C
None Socket Clevis
-- SA07 CA06
7 7 7
2/0 Sol. To 500 Str.
30,000 (13,608) 30,000 (13,608) 25,000 (11,340)
11.0 (4.99) 12.35 (5.60) 12.7 (5.76)
.36-.84 (8.89-21.34)
1/2 (12.70)
3
4
NOTES:
(1) Sag Eye Ultimate Strength is 60% of Clamp strength without fitting. (2) Rated slip strength as a % of conductor RBS varies with cable size and stranding. Minimum slip strength on standard shield wire cables is 40% RBS (Partial Tension). For many shield wire cables, minimum slip strength of this clamp series is 60% RBS (Normal Tension). (Consult factory for slip strength test data on specific clamp & conductor combinations). (3) Recommended torque on u-bolts: 1/2” -- 480 in-lbs. (4) Bolt and Nut may be substituted for clevis pin by adding suffix “BNK” to catalog number.
Copperweld ® is a registered trademark of Fushi Copperweld Inc.
ANDERSON ™
HUBBELL ® POWER SYSTEMS
FARGO ®
December 2014
Made with FlippingBook - Online Brochure Maker