NEMA FULL VOLTAGE POWER DEVICES, CONTROL SECTION 1

1-18

— CR309 magnetic reversing starters Non-combination, open, NEMA type 1, 3R, 12, 4/4X NEMA sizes 00-7 with thermal overload relay 600 volts maximum 50/60 hertz

Three-phase Includes a holding interlock, mechanical and cross- electrical interlock on each contactor, pressure terminals for the line and load connections, plus a 3-leg block type overload relay (manual reset). One NO isolated contact on the overload relay is available as a option. To order add suffix LAA to Product Numbers listed in table for Enclosed types, and Open forms with horizontal mechanical interlock only. Three heaters should be ordered as separate items. See pages 1-153 to 1-159 for selection.

CR309, three-phase magnetic reversing starters

Open Type w/ Vertical Mechanical Interlock

Open Type w/ Horizontal Mechanical Interlock

NEMA Type 4/4X

NEMA Type 3R

NEMA Type 12 3

NEMA Type 1

Continuous Ampere Rating 1

NEMA Size

Voltage (60 Hz)

Horsepower

Product Number CR309

Product Number CR309

Product Number CR309

Product Number CR309

Product Number CR309

Product Number CR309

00 9 00 9 00 9 00 9 00 9

Separate Control—115-120 V

– – – – –

A002 A023 A003 A004 A005

A102 A123 A103 A104 A105 B102 B123 B103 B104 B105 C102 C123 C103 C104 C105 D102 D123 D103 D104 D105 E102 E123 E103 E104 E105 F102 F123 F103 F104 F105 G102 G123 G103 G104 G105

– – – – –

– – – – –

– – – – –

200-208 230-240 460-480 575-600 200-208 230-240 460-480 575-600 200-208 230-240 460-480 575-600 200-208 230-240 460-480 575-600 200-208 230-240 460-480 575-600 200-208 230-240 460-480 575-600 200-208 230-240 460-480 575-600 440-600 440-600

1 1/2 1 1/2

2 2

0 0 0 0 0 1 1 1 1 1 2 2 2 2 2 3 3 3 3 3 4 4 4 4 4 5 5 5 5 5 6

18 18 18 18 18 27 27 27 27 27 45 45 45 45 45 90 90 90 90 90

Separate Control—115-120 V

B002CAA B002 B023CAA B023 B003CAA B003 B004CAA B004 B005CAA B005 C002CAA C002 C023CAA C023 C003CAA C003 C004CAA C004 C005CAA C005 D002AMA D002 D023AMA D023 D003AMA D003 D004AMA D004 D005AMA D005 E002AMA E002 E023AMA E023 E003AMA E003 E004AMA E004 E005AMA E005 F002AMA F002 F023AMA F023 F003AMA F003 F004AMA F004 F005AMA F005 G002AMA G002 G023AMA G023 G003AMA G003 G004AMA G004 G005AMA G005

B602 B623 B603 B604 B605 C602 C623 C603 C604 C605 D602 D623 D603 D604 D605 E602 E623 E603 E604 E605 F602 F623 F603 F604 F605 G602 G623 G603 G604 G605

B202 B223 B203 B204 B205 C202 C223 C203 C204 C205 D202 D223 D203 D204 D205 E202 E223 E203 E204 E205 F202 F223 F203 F204 F205 G202 G223 G203 G204 G205

B402 B423 B403 B404 B405 C402 C423 C403 C404 C405 D402 D423 D403 D404 D405 E402 E423 E403 E404 E405 F402 F423 F403 F404 F405 G402 G423 G403 G404 G405

3 3 5 5

Separate Control—115-120 V

7 1/2 7 1/2

10 10

Separate Control—115-120 V

10 15 25 25 25 30 50 50

Separate Control—115-120 V

135 135 135 135 135 270 270 270 270 270 540 810

Separate Control—115-120 V

40 50

100 100

Separate Control—115-120 V

75

100 200 200 400

– –

2

2

2

2

2

7

600

2

1 Motor full load current should not exceed continuous ampere rating of the starter. 2 Order by description giving complete data on motor being controlled, control circuit voltage, enclosure type and modifications desired. 3 External reset not included on standard listed forms.