LOAD CENTERS, ASSOCIATED CIRCUIT BREAKERS, AND ACCESSORIES, BUYLOG SECTION 1
1-8
— PowerMark PRO load centers
Main lug, factory installed, indoor (NEMA 1) enclosure, top/bottom feed 1
1 pole, 1” spaces
2 pole, 1” spaces
Total 1-pole spaces
Max single pole circuits
Main wire size (AWG/kcmil) Cu-Al
Front type
Equipment ground kit
Ordering code
Main ampere rating
125
12 24 32 32 40 42
6
12 24 32 32 40 42
24 48 64 64 80 84
Combination Combination Combination Combination Combination Combination
6-2/0 TGK12 and TNLK20 installed 6-2/0 TGK 24 and TNLK20 installed 6-2/0 TGK32 and TNLK20 installed 6-250 TGK32 and TNLK20 installed 6-250 TGK42 and TNLK20 installed 1-300 TGK42 and TNLK20 installed
PLM1212C 2 PLM2412C 2 PLM3212C 2 PLM3220C 3 PLM4020C 3 PLM4222C 3
12 16 16 20 20
200
225
1 PLM indicates units are convertible to main breaker 2 For main breaker, order TQMH000. See page 1-48. Also order 2-pole THQL, THHQL, or TXQL circuit breaker. See page 1-43 3 For main breaker, order THQMVXXXE circuit breaker from page 1-48.
Main lug, factory installed, indoor (NEMA 1) enclosure, top/bottom feed, white trim 1
1 pole, 1” spaces
2 pole, 1” spaces
Total 1-pole spaces
Max single pole circuits
Main wire size (AWG/kcmil) Cu-Al
Front type
Equipment ground kit
Ordering code
Main ampere rating
125
12 24 32 32 40 42
6
12 24 32 32 40 42
24 48 64 64 80 84
Combination Combination Combination Combination Combination Combination
6-2/0 TGK12 and TNLK20 installed 6-2/0 TGK 24 and TNLK20 installed 6-2/0 TGK32 and TNLK20 installed 6-250 TGK32 and TNLK20 installed 6-250 TGK42 and TNLK20 installed 1-300 TGK42 and TNLK20 installed
PLM1212W 2 PLM2412W 2 PLM3212W 2 PLM3220W 3 PLM4020W 3 PLM4222W 3
12 16 16 20 20
200
225
1 PLM indicates units are convertible to main breaker 2 For main breaker, order TQMH000. See page 1-48. Also order 2-pole THQL, THHQL, or TXQL circuit breaker. See page 1-43 3 For main breaker, order THQMVXXXE circuit breaker from page 1-48.
Main lug, factory installed, outdoor (NEMA 3R) enclosure, top/bottom feed 1
1 pole, 1” spaces
2 pole, 1” spaces
Total 1-pole spaces
Max single pole circuits
Main wire size (AWG/kcmil) Cu-Al
Front type
Equipment ground kit
Ordering code
Main ampere rating
125 200
24 32 40
12 16 20
24 32 40
48 64 80
– – –
6-2/0 TGK24 and TNLK20 installed 6-250 TGK32 and TNLK20 installed 6-250 TGK42 and TNLK20 installed
PLM2412R 2 PLM3220R 3 PLM4020R 3
1 PLM indicates units are convertible to main breaker 2 For main breaker, order TQMH000. See page 1-48. Also order 2-pole THQL, THHQL, or TXQL circuit breaker. See page 1-43 3 For main breaker, order THQMVXXXE circuit breaker from page 1-48.
NOTE: Circuit breakers must be ordered separately. Click here.