BuyLog Flippingbook MAR 2024

METERING, BUYLOG SECTION 2

2-45

— ReliaMod™ Accessories

ReliaMod™ replacement wall mounting accessories (continued on next page) (continued)

ReliaMod™ product

Meter modules

Main modules

Accessories

Main fusible switch modules (standard)

Main breaker

MLO modules (feed through) See below Pull boxes

Main fusible switch (EUSERC)

Main breaker modules (EUSERC)

Main breaker modules (standard)

Wall rail width (in)

Wall rail replacement kit Ordering code RWALLRAIL23

MLO modules (standard)

modules (with lug landing pad)

Surge modules

Elbows

23

400A commercial lever bypass meter modules

600A- 800A MCB

600A- 800A MFS

800A pull box

RWALLRAIL25

25

1400A through

1600A MCB (4-cable lug design)

RWALLRAIL29

29

1200A MLO feed through 1600A- 2000A MLO feed through

1200A pull box

RWALLRAIL33

33

1000A- 1200A MCB

1600A- 2000A MLO

RWALLRAIL39

39

1400A- 2000A MCB (6-cable lug design)

1400A-1600A MCB with lug landing pad

Note: Replacement wall rails are specific to the enclosure they are being used for and have specific order code numbers based on the enclosure width. Be sure to select the correct order code number in the table above based on your unique ReliaMod™ enclosure that you need a replacement wall rail for. Note: Replacement wall rails do not come with mounting hardware to mount them to the wall. This is because there are many different types of wall material they can be mounted to that would require different hardware, many different local or regional code requirements, and any applicable seismic requirements. Replacement wall rail mounting hardware is to be provided by others. Note: Replacement wall rails mount to the wall and not on the ReliaMod™ enclosure. See enclosure rail brackets below if you need a replacement bracket to mount to the ReliaMod™ enclosure. Note: ReliaMod™ spacers and bus adapters are small enough that they do not require wall rails and are not listed above as they only come with wall swivel brackets for mounting. However, ReliaMod™ pull boxes, surge modules, and elbows indeed do come with wall rails as outlined in the above table.

Replacement enclosure rail bracket Ordering code

Description

RENCLOSURERAIL¹

Kit of 3 replacement enclosure rail brackets with hardware (The enclosure rail bracket mounts to the ReliaMod™ enclosure vs the wall rail bracket which mounts to the wall that the enclosure rail rests on)

Replacement wall swivel brackets Ordering code

Description

RWALLBRACKETS² Kit of 6 wall swivel brackets with hardware ¹ These enclosure rail brackets apply to all ReliaMod™ enclosures, unlike wall rails in the table above that have specific order code numbers for certain ReliaMod™ enclosure designs and widths. ²These swivel brackets apply to all ReliaMod™ enclosures, unlike wall rails that have specific order code numbers for certain enclosure designs and widths

Made with FlippingBook Ebook Creator