Bullard IHS Catalog
Spectrum Series ®
Spectrum Series® Continuous Flow Replacement Parts
10
9
8A
1
8
7
6D
6C
6B
2
4
6A
6
3
5
11A
12
11
Cat. No. Description 8. EVO (includes parts listed) O-ring for Exhalation Valve Seat 8A Exhalation Valve Seat 9. LNK Nose Cup 10. SPECIVK Inhalation Valve Flaps 11. SPECBT Breathing Tube Assembly 11A Breathing Tube Adapter 12. LC Mylar® Lens Covers
Cat. No.
Description
1. LCK 2. RLS
Lens Clamp Replacement
Replacement Lens Facepiece Flange
3. FKML & FKS
4. HSK 5. MCK
Headstrap with Buckles and Slides
Mask Cover 6. SEK (includes parts listed) Speaker Diaphragm 6A Outer Locking Ring 6B
O-ring Speaker Diaphragm O-ring Speaker/Exhalation Speaker/Exhalation Body
6C 6D
7. 6059
Exhalation Valve
Continuous Flow Airline Respirator
A complete Spectrum Series® Continuous Flow Airline Respirator consists of the following three components: 1. Full-Facepiece
2. Breathing Tube Assembly 3. Breathing Air Supply Hose
1
All three Bullard components must be present and properly assembled to constitute a NIOSH approved respirator. Approval No. TC-19C-322, Type C, Continuous Flow Class
2
3
165
www.bullard.com
Made with FlippingBook Publishing Software