Control Catalog

NEMA Full Voltage Power Devices NEMA Rated Full Voltage Starters - Magnetic

Section 1

CR306, CR307, CR308, CR309, CR310, CR311, CR387, CR390, CR407, CR408, CR410, CR411, CR487, CR490 Magnetic Starters Factory-Installed Modifications Starter Modifications—Factory Installed The general information at the top of page 1-124, regarding factory-installed modifications, also applies to those listed in the table below.

Starter NEMA Size

Type of Installation/ Starters Pilot Devices Mounted in Cover or Flange of CR309, CR410, CR411, CR490

00

0

1

2

3

4

5

6

Item No .

Enclosure Type

Modifications

List Price Addition, GO-10G

7 Indicating Lights (Specify Color) 1 7a Two

2 $324.00 $324.00 $324.00 $324.00 $324.00 $324.00 $324.00 2 $618.00 $618.00 $618.00 $618.00 $618.00 $618.00 $618.00 2 $360.00 $360.00 $360.00 $360.00 $360.00 $360.00 $360.00 2 $672.00 $672.00 $672.00 $672.00 $672.00 $672.00 $672.00

Any

7b Three

Any

7c Two Push-To-Test

Any

7d Three Push-To-Test

Any

Separate Control Circuit (Specify Voltage and Frequency, Reference Items 13a and 13b for Standard Voltages)

N/C

N/C

N/C

N/C

N/C

N/C

N/C

N/C

8

Any

2 $132.00 $132.00 $132.00 $132.00 $132.00 $132.00 $132.00

9 Fused Control Circuit—Two Fuses

Any

Control Transformer—Standard Capacity, 50 or 60 Hertz 3 Two Primary and One Fuse Secondary, (Specify Voltage Rating) Standard Voltages at 60 Hertz 220-230-240 Primary, 110-115-120 Secondary 440-460-480 Primary, 110-115-120 Secondary 550-575-600 Primary, 110-115-120 Secondary 200-208 Primary, 115-120 Secondary

Control Circuit in

2 $294.00 $294.00 $352.00 $468.00 $540.00 $594.00 $594.00

10

Any

CR306 CR307 CR308 CR309 CR310 CR311 CR387 CR390 CR407 CR408 CR410 CR411 CR487 CR490

2

$420.00 $420.00 $504.00 $600.00 $660.00 $720.00 $720.00

11 Control Transformer—100 VA Additional Capacity, 60 Hertz

Any

12 13 Operating Coil 13a 6 Standard Voltages at 60 Hertz:

N/C

N/C

N/C

N/C

N/C

N/C

6

6

Any

24, 115-120, 200-208, 230-240, 460-480, 575-600

N/C

N/C

N/C

N/C

N/C

N/C

N/C

N/C

13b Standard Voltages at 50 Hertz: 110, 220, 380-415, 440, 550

Any

13d 4 DC—Standard Voltages: 24, 115-125

5

5

$102.00 $114.00 $198.0 0 $264.00 $720.00 $720.00

Any

4 Available in CR305 Contactor forms. 5 Not available in NEMA Sizes 00 or 0. Use Size 1 contactor and modification. 6 24V coil not available on size 5 and 6.

1 Two indicating lights have each one wired in parallel with each operating coil. (Both red or red/amber or red/green.) Three lights have one wired in parallel with each operating coil with the third one wired through two normally closed auxiliary contacts. (Both red or red/amber, with green "OFF.") 2 Not available in NEMA Size 00. Use size 0 starter and modification. 3 The National Electrical Code, Article 450-3(B), requires primary fuses in most typical installations. Refer to the NEC, Article 450 prior to ordering control transformer without primary fuses to insure compliance. Control circuit fuse kits from page 1-136 may be used to provide primary fusing. Fuses must be sized to meet the requirements of the NEC according to the "Recommended Fuse" table. Control Circuit Fusing Per the NEC and UL508 Section 18.2 - Control Circuit Fuses must be used when the branch circuit protective device rating is too large to serve as protection for the control circuit . This depends on the control wire size and whether all control circuit wires are within the enclosure. See table below: Provide supplemental control circuit protection if control circuits with wires longer than 12 inches are connected to branch circuit protection exceeding the ratings below Control Maximum Branch Circuit Maximum Supplemental Circuit Protection Rating (Amperes) Control Circuit Wire Size Conductors Conductors Protection Rating (AWG) within Enclosure outside Enclosure (Amperes) 22 12 3 3 20 20 5 5 18 25 7 7 16 40 10 10 14 100 45 20 12 120 60 25

Recommended Fuse

Primary Voltage

208/240

480

600

CPT VA

50

1

0.5

0.5

1

100 150 250 300

2 3

0.75

2 1 2

1.5

2 3

5 6

The factory must provide this protection, if the circuit provided by the factory requires the fuses. The factory will provide control circuit fuses in enclosed starters and contactors with pilot devices, control relays or other control components that are factory wired; when used with line voltage control; when the size listed below is being supplied. Non-combination starters (CR305, CR306, CR309, CR385, CR386) Size 4 and above Combination starters Size 0-3 with Mag-Break Protector Size 3 with: —Circuit Breaker greater than 100 amps, or —Fuse Clips greater than 100 amps, or Size 4 and above with any circuit breakers, circuit protector or fuse clips. Control Circuit fuses (Modification 9) must be added to the enclosed starter or contactor pricing. All CPTs will be supplied with primary fuses. CPTs without primary fuses are no longer available. When control circuit fuses are not factory supplied, customer provided wiring or branch circuit protection sizing to these contactors and starters may still require that the customer/installer add the fusing in the field. It will be the customer/installer’s responsibility to ensure code compliance under these conditions.

Heater Selection Tables: See pages 1-153 to 1-159