Control Catalog
NEMA Full Voltage Power Devices NEMA Rated Full Voltage Contactors
Section 1
CR305, CR385 Magnetic Contactors Factory-Installed Modifications
Contactor Modifications—Factory Installed The general information at the top of page 1-197, regarding factory-installed modifications, also applies to those listed in the tables below.
NEMA Size
Type of Installation/ Contactors
00
0
1
2
3
4
5
6
Item No.
Enclosure Type
Modifications
List Price Addition, GO-10G
4 Indicating Light 1 4a One (Red Only) 2
$90.00
$90.00
$90.00
$90.00
$90.00
$90.00
$90.00 $162.00
1
Pilot Devices Mounted In Cover or Flange of CR305
One (Specify Red or Green) (HEAVY-DUTY, CR104P)
3
4b
$162.00 $162.00 $162.00 $162.00 $162.00 $162.00 $162.00
Any
Two (Includes 1 NC Auxiliary Contact) 4 (HEAVY-DUTY, CR104P) One Push-To-Test and/or Transformer Type (Red or Green) Two Push-To-Test (Includes 1 NC Auxiliary Contact) and/or Transformer Type 4
3
$390.00 $390.00 $390.00 $390.00 $390.00 $390.00 $390.00
Any
4c
3
$180.00 $180.00 $180.00 $180.00 $180.00 $180.00 $180.00
4d
Any
3
$426.00 $426.00 $426.00 $426.00 $426.00 $426.00 $426.00
4e
Any
1 One indicating light: Wired in parallel with operating coil. Two indicating lights: Red is wired in parallel with operating coil, green is wired through an auxiliary contact . 2 Factory-installed field modification kit for sizes 00-4 and size 5 without CPT. 3 Not available in NEMA Size 00. Use Size 0 contactor modification. 4 Maximum of three additional auxiliary contacts available on size 0-1.
NEMA Size
Type of Installation/ Contactors
00
0
1
2
3
4
5
6
Item No.
Enclosure Type
Modifications
List Price Addition, GO-10G
8 Separate Control Circuit (Specify Voltage and Frequency, Reference Items 13a and 13b for Standard Voltages)
N/C
N/C
N/C
N/C
N/C
N/C
N/C
N/C
Any
1 $132.00 $132.00 $132.00 $132.00 $132.00 $132.00 $132.00
9 Fused Control Circuit—Two Fuses
Any
Control Transformer—Standard Capacity, 50 or 60 Hertz 2 Two Primary and One Fuse Secondary, (Specify Voltage Rating) Standard Voltages at 60 Hertz 220-230-240 Primary, 110-115-120 Secondary 440-460-480 Primary, 110-115-120 Secondary 550-575-600 Primary, 110-115-120 Secondary 200-208 Primary, 115-120 Secondary
Control Circuit in CR305
1 $294.00 $294.00 $352.00 $468.00 $540.00 $594.00 $594.00
Any
10
1
$288.00 $288.00 $372.00 $468.00 $528.00 $588.00 $588.00
11 Control Transformer—100 VA Additional Capacity, 60 Hertz
Any
12 13 Operating Coil 13a 4 Standard Voltages at 60 Hertz:
N/C
N/C
N/C
N/C
N/C
N/C
N/C
N/C
Any
24, 115-120, 200-208, 230-240, 460-480, 575-600
N/C
N/C
N/C
N/C
N/C
N/C
N/C
N/C
13b Standard Voltages at 50 Hertz: 110, 220, 380-415, 440, 550
Any
3
3
$198.0 0 $264.00 $720.00 $720.00
$102.00 $114.00
Any
13d DC—Standard Voltages: 24, 115-125
1 Not available in NEMA Size 00. Use size 0 contactor modification. 2 The National Electrical Code, Article 450-3(B), requires primary fuses in most typical installations. Refer to the NEC, Article 450 prior to ordering control transformer without primary fuses to insure compliance. Control circuit fuse kits from page 1-206 may be used to provide primary fusing. Fuses must be sized to meet the requirements of the NEC according to the table below.
3 Not available in NEMA Sizes 00 or 0. Use Size 1 contactor modification. 4 24V coil not available on size 5 and 6.
Recommended Fuse
Primary Voltage
CPT VA
208/240
480
600
50
1 2 3 5 6
0.5
0.5
100 150 250 300
1
0.75
1.5
1 2 2
2 3
Other Coil Voltages: See page 1-6 Factory Installed Modifications: See pages 1-197 to 1-201 Field Installed Modifications: See pages 1-202 to 1-207
Rev. 4/16 Prices and data subject to change without notice