Control Catalog
NEMA Full Voltage Power Devices NEMA Rated Full Voltage Starters - Magnetic
Section 1
CR308 Magnetic Starters Nonreversing, Combination, Nonfusible and Fusible Disconnect Type Part Number Configuration Valid for NEMA sizes 0-2, Type 1 Standard Enclosure
Step 6 (Digit 14) Select Monitoring Options
List Price GO-10G1
Device
Code
None 3 $0.00 3 Phase Failure Relay is not available for CR308 series standard enclosures. If this is required for your application, use CR408 series oversized enclosure. See page 1-37. A
Step 7 (Digit 15) Select Push Button/Selector Switch
List Price GO-10G1
Push Button/Selector Switch - Heavy Duty
Code
$0.00
None
A
$132.00 $132.00 $132.00 $264.00 $168.00
Start/Stop Push Button
J L
Hand-Off-Auto (HOA) Selector Switch
Off-On Selector Switch
M
HOA SS & Start Push Button
S
Keyed HOA SS, Key Removal Center Pos.
N
Step 8 (Digit 16) Select Pilot Device Pilot Light (Heavy Duty)
List Price
Type
Color - Functionality
Code GO-10G1
$0.00
None
A
$162.00 $162.00 $228.00 $228.00 $456.00 $390.00 $552.00 $162.00 $162.00 $228.00 $228.00 $456.00 $390.00 $552.00 $180.00 $180.00 $246.00 $246.00 $492.00 $426.00 $606.00
Red - Across Coil Green - Across Coil
J
K
M 4 N 4 U 5
Red - Thru NO Aux Contact Green - Thru NC Aux Contact
Standard Lights
Red - Thru NO Aux Contact & Green - Thru NC Aux Contact
T 4 X 4
Red - Across Coil & Green - Thru NC Aux Contact
Red - Across Coil & Green - Thru NC Aux Contact & Unwired Amber
Red - Across Coil Green - Across Coil
1 2
3 4 4 4 5 5 6 4 7 4 C 4 D 4 E 5 V 4 Y 4 R S
Red - Thru NO Aux Contact Green - Thru NC Aux Contact
LED Lights
Red - Thru NO Aux Contact & Green - Thru NC Aux Contact
Red - Across Coil & Green - Thru NC Aux Contact
Red - Across Coil & Green - Thru NC Aux Contact & Unwired Amber
Red - Across Coil Green - Across Coil
Red - Thru NO Aux Contact Green - Thru NC Aux Contact
Push-To-Test Lights
Red - Thru NO Aux Contact & Green - Thru NC Aux Contact
Red - Across Coil & Green - Thru NC Aux Contact
Red - Across Coil & Green - Thru NC Aux Contact & Unwired Amber
4 Maximum of 3 Aux contacts may be added to Sizes 0 & 1. 5 Maximum of 2 Aux contacts may be added to Sizes 0 & 1. Maximum of 3 Aux contacts may be added to Sizes 2-4. Note: Auxiliary contacts wired as part of pilot light selection are in addition to the auxiliary contacts selected from Step 5 (Digit 13) Table, page 1-35, which are for customer/field connections.
Step 9 (Digit 17) Select Control Options List Price Device Code GO-10G1 None A $0.00
GENERAL NOTE: On NEMA Size 3 & 4 starters, if selecting factory installed and wired operator devices (Push Buttons, Selector Switches, and/or Pilot Lights) then control circuit fusing, a control power transformer, or 120V separate sourced control is required when the protective device is rated greater than 100 Amps.
Rev. 4/16 Prices and data subject to change without notice
Control Catalog
www.geindustrial.com
1-36
Made with FlippingBook - Online catalogs