CIS Microsoft Windows 10 Enterprise Release 1909 Benchmark
All PDC Emulator operations masters follow the hierarchy of domains in the selection of their inbound time partner. The PDC Emulator operations master at the root of the domain is authoritative for the organization. Therefore it is recommended that you configure this computer to synchronize with a reliable external time server. This vulnerability becomes much more serious if an attacker is able to change the system time and then stop the Windows Time service or reconfigure it to synchronize with a time server that is not accurate.
Audit:
Navigate to the UI Path articulated in the Remediation section and confirm it is set as prescribed.
Remediation:
To establish the recommended configuration via GP, set the following UI path to Administrators, LOCAL SERVICE :
Computer Configuration\Policies\Windows Settings\Security Settings\Local Policies\User Rights Assignment\Change the system time
Impact:
There should be no impact, because time synchronization for most organizations should be fully automated for all computers that belong to the domain. Computers that do not belong to the domain should be configured to synchronize with an external source.
Default Value:
Administrators, LOCAL SERVICE.
References:
1. CCE-33094-4
85 | P a g e
Made with FlippingBook - Online magazine maker