Chromalox European Product Catalog

LIQUID HEATING / CHAUFFAGE DES LIQUIDES

TRHGV77

Hazardous area immersion heater with M77 screw plug Thermoplongeurs avec bouchon M77 pour zone explosive

• Immersion heaters for water or oil • ATEX II 2 G - Ex db II C T1 to T6 certified • Stood off, painted IP55 mild steel terminal enclosure, supplied with glands • M77 / 200 ISO brass or AISI 316L screw plug, in accordance to the range • Ø 12.8mm or 16mm AISI 316L or Incoloy 825 sheathed elements, according to the range • Watts density • 2, 4, 10, or 12 W / sq. cm (water heating) • Maximum operating pressure: 10 bars (brass screw plug) • 20 bars (stainless steel plug) • Built in pocket for optional sensor, thermostat, or cutout • 5 Inches terminal enclosure with intensity max 40A, consult us for other size. • NOTE: add the requested temperature class (T1, T2, T3, T4, T5, or T6) at the end on the reference

• Thermoplongeurs pour eau ou huile • Certifiés ATEX II 2 G - Ex db II C T1 à T6 • Boîtier décalé acier peint IP55 livré avec PE • Bouchon fileté M77 / 200 ISO, en laiton ou en inox suivant gamme • Eléments chauffants Ø 12,8 ou 16mm blindés inox AISI 316L, ou incoloy 825 suivant gamme • Charge • 2, 4 / 10 / ou 12 W / cm2 (chauffage d’eau) • Pression maximale d’utilisation : 10 bars (bouchon laiton) 20 bars( bouchon inox) • Doigt de gant intégré pour sonde, thermostat, ou limiteur optionnel • Boitier 5 pouces avec intensité max 40A, autre dimension sur demande. • NOTA : a jouter la classe de température désirée (T1, T2, T3, T4, T5, ou T6) en fin de référence

Accessories / Accessoires

Reference / Référence

Brass backnut / Ecrou laiton

Ref : E0077 Ref : J0077 Ref : JCU077 Ref : JIN077 Ref : B0077 Ref : BIN077

Sheath elements and screw plug Stainless steel AISI 316L Eléments et bouchon Inox AISI 316L (4W/cm2)

Incoloy 825 sheath and brass screw plug Blindage Incoloy 825 et bouchon laiton (10W/cm2)

Rubber gasket / Joint caoutchouc

AISI 321 sheath and brass screw plug Blindage AISI 321 et bouchon laiton (4W/cm2)

Weight Poids kg

Ouput Puissanc e W

Length X Cote X (mm)

Cold NC (mm)

Copper/ rubber gasket / Joint cuivre caoutchouc Stainless steel gasket / Joint inox Steel weld ring / Bague à souder acier Stainless steel ring / Bague à souder inox

TRHGV77HI020 TRHGV77HI030

2000 3000 3500 4000 4000 6000 6000 6000 8000 9000 9000

380 540 360 235 650 285 570

70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70

17

Number of baffles Nbre d’ailettes de dissipation

17,9 16,9 15,8 18,5

“d” stand off Déport “d”

Max liquid temperature Température de liquide maxi °C

TRHGV77I035

TRHGV77IE040

170°C

140 mm

0

TRHGV77HI040

250°C

220 mm

2

TRHGV77IE060

16

204°C for Glycol and T3 class Pour Glycol et classe T3

TRHGV77I060

18,1 20,5

220 mm

3

TRHGV77HI060 TRHGV77HI080

1010 1290

22

TRHGV77IE090

395 830

16,5 19,5 23,6 20,9 25,2 17,4 18,2 18,8 19,8 21,2 22,7 22,7 17

TRHGV77I090

TRHGV77HI100

10000 12000 12000 12000 15000 20000 24000 30000 40000 50000

1580

TRHGV77IE120

505

TRHGV77I120

1080 1880

TRHGV77HI120

TRHGV77IE150 TRHGV77IE200 TRHGV77IE240 TRHGV77IE300 TRHGV77IE400 TRHGV77IE500

605 785 935

1150 1480 1830

TRHGV77IE 500

50 000 1 830

* Note: Weights are given for d = 140mm * Nota : Les poids sont donnés pour d = 140mm

BUILT IN TEMPERATURE SAFETY DEVICE (OPTION) FOR TRHGV 77 • By fail safe and automatic reset cutout (fault memorizing and manual reset have to be provided in the control panel) • By fail safe and manual reset cutout • By Pt100 sensor (the sensor will have to be connected to a fail safe controller • + fault memorizing device installed in the control panel) • Consult our technical department

SECURITÉ TEMPÉRATURE INTEGRÉE (OPTION) POUR TRHGV77

• Par thermostat à sécurité positive et à réarmement automatique (mémorisation défaut et réarmement manuel à prévoir au niveau de l’armoire de commande) • Par limiteur à sécurité positive et à réarmement manuel • Par sonde Pt100 (à raccorder sur un contrôleur à sécurité positive • + système de mémorisation défaut et réarmement manuel, à prévoir au niveau de l’armoire de commande) • Consultez nos services techniques

10 - C - 12