Type C PORCELAIN Cutouts (Standard, Linkbreak, Loadbreak) and Cutout-Arrester Combinations (10A)

All Type C Cutouts meet or exceed ANSI/NEMA specifications.

Type C 100-Amp LINKBREAK Cutout

*Fuseholders (100 Amp only)

kV & BIL 15 kV 110 kV BIL 15/27 kV

Cutout Catalog Number

Fuseholder Catalog No. T720112T T720114T T720211T T720213T T720311T T720313T T720613T

Weight

lb. 2.5 2.7 2.7 2.9 2.7 2.9 3.5

kg. 1.13 1.22 1.22 1.32 1.22 1.32 1.59

C720112PB C720114PB C720211PB C720213PB C720311PB C720313PB C720613PB

125 kV BIL 22/36.4 kV 150 kV BIL 22/36.4 kV 170 kV BIL *Mounting assemblies are same as Type C STANDARD cutouts, shown onpage 10A-7.

110 kV BIL

125 & 150 kV BIL

170 kV BIL

See page 10A-15 for Accessories.

Specifications and Ordering Information 15 kV - 110 kV LIW (BIL)  —  RUS Listed

*Option suffixes below  1  2 3  1  2 3

Maximum Design Voltage

Continuous Current (Amps)

Interrupt Capacity (Asym Amps)

Arc Shortening Rod No Yes ‡

Replacement Fusetube Cap P7001469P E7001784P

*Weight (lb./kg.)

*Base Catalog No.

Nominal System Voltage Thru 14.4 kV Thru 14.4 kV

Leakage to Ground Metal to Metal

220 mm 220 mm

14.53 /6.59 14.73 /6.68

C720112 C720114

15 kV 15 kV

100 100

10,000  16,000

8.7" 8.7"

22/36.4 kV 22/36.4 kV 22/36.4 kV - 150 kV LIW (BIL)  —  RUS Listed C720311 C720313 No Restrictions thru 20.8 kV; † 22.8 thru 34.5 kV 100 15/27 kV - 125 kV LIW (BIL)  —  RUS Listed No Restrictions thru 14.9 kV; † 20.8 thru 24.9 kV 1  2 3 1  2 3 1  2 3 1  2 3 C720211 C720213 15/27 kV 15/27 kV 100 100

8,000 

No

12.6"

320 mm

17.23 /7.82

P7001469P

12,000

Yes ‡

12.6"

320 mm

17.43 /7.91

E7001785P

23.03/10.45

8,000 

440 mm

P7001469P

17.3"

No

23.23/10.54

12,000

440 mm

E7001785P

17.3"

Yes ‡

100

22/36.4 kV -170 kV LIW (BIL)  —  RUS Listed

No Restrictions thru 20.8 kV; † 22.8 thru 34.5 kV

1  2 3

22/36.4 kV

C720613

100

11,200

26.0"

660 mm

26.13/11.85

PE7001787P

Yes ‡

‡ Must use removable buttonhead fuse links. NOTE: 26" fuse links are recommended.

*Adjust total weight when selecting Options below.

† For application on single-phase to neutral circuits with phase-to-ground voltages not exceeding the value to the left of the slant; and for application on three-phase solidly-grounded-wye systems with solidly-grounded loads with line-to-line voltages not exceeding the value to the right of the slant.

*Option Suffix 2 Bracket Variations

*Option Suffix 3 Mechanical Assist Fuseholder

*Option Suffix 1 Terminal Variations

Suffix 2 B

*Weight (lb./kg.) 2.84/1.29

*Weight (lb./kg.)

Suffix 1

Description NEMA Heavy Duty “B” bracket for crossarm (1 1 / 2 " bolt) Extended type bracket for crossarm (Horizontal section is 2 5 / 8 " longer than Type B bracket) D-shape bracket (pole) No bracket (must be used with M in Option 3) No bracket (cannot use with M in Option 3) Easy-On bracket (Height: 4 1 ⁄ 8 " to 5 5 ⁄ 32 ", Width: 2 3 ⁄ 4 " to 4")

Description

Suffix 3 Blank

Description

P E L R

Parallel-groove clamps Small eyebolts Large eyebolts Lower PG Clamp Rotated 90°

0.33/0.15 0.16 /0.07 0.31/0.14 0.33/0.15

No option (may not be used with Z in Option 2) Mechanical Assist Fuse- holder (may not be used with Blank in Option 2)

3.75/1.70

X

M

D Z

7.67/3.48 –––

Must specify one selection for Option 1.

Fargo cutout cover (available for 15 kV

F

only) (may not be used with Blank in Option 2)

–––

Blank

V

2.9/1.32

Phone: 573-682-5521 Email: hpsliterature@hubbell.com Web: hubbellpowersystems.com

Page 10

January 2014