NASCOM DATABOOK 2014 - page 35

Royne Industries LLC, dba NASCOM | P: 800.843.5530 | F: 800.727.4041 |
2
DWG No. 131125-24 Rev. 1
.125
3.18
.475
12.07
2.585
65.66
.525
13.34
2.140
54.36
.140
3.56
.265
6.73
.425
10.80
.215
5.46
.140
3.56
.475
12.07
.751
19.06
2.585
65.66
TOP
VIEW
TOP
VIEW
FRONT VIEW
FRONT VIEW
TOP
VIEW
FRONT VIEW
END
VIEW
END
VIEW
END
VIEW
.475
12.07
.125
3.18
2.585
65.66
.525
13.34
2.140
54.36
.140
3.56
.264
6.71
FRONT VIEW
TOP
VIEW
DIMENSIONS - IN [mm]
SWITCH
MAGNET
.125
3.18
2.140
54.36
2.585
65.66
.525
13.34
.165
4.19
FRONT VIEW
TOP
VIEW
SPACER
WIRING SCHEMATIC
SWITCH
CONTACT
SWITCH
CONTACT
OPEN LOOP,
NORMALLY CLOSED CONTACT
CLOSED LOOP,
NORMALLY OPEN CONTACT
SPDT, SINGLE POLE DOUBLE THROW
COMMON
(BROWN)
NC, OPEN LOOP (WHITE)
NO, CLOSED LOOP (RED)
INSTALLATION INSTRUCTIONS
Note: High Security model – Dots on switch and magnet must be aligned for correct operation.
Position the switch on the door/window frame in the desired location as close to the movable part of the door /window as possible.
Mark the switch mounting screw locations and drill the mounting screw holes using a drill adequately sized for #6 self-tapping screws.
Install screws and tighten to mount the switch on the door/window frame.
Position the magnet on the movable part of the door/window, align the magnet with the switch as close as possible. For steel door or
window applications, use the enclosed spacer under the magnet.
Mark the magnet mounting screw locations and drill the mounting screw holes using a drill adequately sized for #6 self-tapping screws.
Install screws and tighten to mount the magnet on the door/window.
Connect the alarm circuit leads to the terminals on the switch and test the system for correct operation.
Loosen the switch mounting screws and install terminal screw cover. Retighten mounting screws.