NASCOM DATABOOK 2014 - page 71

Royne Industries LLC, dba NASCOM | P: 800.843.5530 | F: 800.727.4041 |
2
DWG No. 131118-06 Rev. 1
.313
7.95
.045
1.14
3M VBH TAPE
.350
8.89
1.375
34.93
12.000
304.80
END VIEW
TOP VIEW
.313
7.95
.045
1.14
3M VBH TAPE
1.375
34.93
.350
8.89
END VIEW
TOP VIEW
DIMENSIONS - IN [mm]
WIRING SCHEMATIC
SWITCH
CONTACT
SWITCH
CONTACT
OPEN LOOP,
NORMALLY CLOSED CONTACT
CLOSED LOOP,
NORMALLY OPEN CONTACT
SWITCH
MAGNET
SPDT, SINGLE POLE DOUBLE THROW
COMMON
(BROWN)
NC, OPEN LOOP (WHITE)
NO, CLOSED LOOP (RED)
DUAL CLOSED LOOP,
NORMALLY OPEN CONTACTS
INSTALLATION INSTRUCTIONS
Pre-fit the switch and magnet in the desired location on the window.
Clean the mounting surface area for both switch and magnet with alcohol and let dry.
Remove the liner from the tape on the back of the switch and carefully position the switch on the window frame as close
as possible to the movable part of the window.
Remove the liner from the tape on the back of the magnet and carefully align the magnet parallel with the switch on the
movable part of the window and as close to the window frame as possible.
Apply firm pressure to the switch and magnet housing to ensure proper adhesion to the mounting surface.
Connect the switch leads to the alarm system circuit.
Caution!
Hold wire leads, not the switch housing while cutting and
stripping to prevent damage to switch.
Test alarm system for correct operation.
N135WG
3/8” STICK ON CONTACT SET, CENTER LEADS
1...,61,62,63,64,65,66,67,68,69,70 72,73,74,75,76,77,78,79,80,81,...232