20
SPLASH ZONE
Photographs are not to scale and are not true representations of the products in question.
If not otherwise specified, all values relating to the product are nominal values. For current information go to our website.
ULTRA HB Series
EPIC
®
ULTRA HB 16 Hoods
Double Lever Bolts
EPIC
®
ULTRA HB 16 Panel Mount Bases
Double Levers
All dimensions are in mm.
All dimensions are in mm.
Technical Data
Specifications:
DIN EN 60529, DIN EN 6988
Temperature Range:
-40°C to +100°C
Protection Class:
IP65, UL 50E,
certified to NEMA 4, 4X & 12
Corrosion Resistance: 72-hour salt spray per DIN EN 60068-2
480-hour salt spray per DIN EN ISO 9227
Material:
See EPIC
®
ULTRA HB Housings material
specifications on page 17
Part Number
Cable OD Range
Min. OD for
Braided Shield
Brush
Side Entry
70250214
7 - 15 mm
—
No
70250215
11 - 21 mm
—
No
70250216
11 - 21 mm 8 mm
Yes
Technical Data
Specifications:
DIN EN 60529, DIN EN 6988
Temperature Range:
-40°C to +100°C
Protection Class:
IP65, UL 50E,
certified to NEMA 4, 4X & 12
Corrosion Resistance: 72-hour salt spray per DIN EN 60068-2
480-hour salt spray per DIN EN ISO 9227
Material:
See EPIC
®
ULTRA HB Housings material
specifications on page 17
Approvals
Description
Part Number
Panel Mount Base
70250217
Approvals