A832 - Spot Lifter Super Dry Formulation

ACGIH Biological Exposure Indices Value Components

Determinant

Specimen Sampling Time

0.5 mg/l

Trichloroethano l, without hydrolysis

Blood

*

* - For sampling details, please see the source document.

Good general ventilation (typically 10 air changes per hour) should be used. Ventilation rates should be matched to conditions. If applicable, use process enclosures, local exhaust ventilation, or other engineering controls to maintain airborne levels below recommended exposure limits. If exposure limits have not been established, maintain airborne levels to an acceptable level. Eye wash facilities and emergency shower must be available when handling this product.

Appropriate engineering controls

Individual protection measures, such as personal protective equipment

Wear safety glasses with side shields (or goggles).

Eye/face protection

Skin protection

Wear appropriate chemical resistant gloves. Suitable gloves can be recommended by the glove supplier.

Hand protection

Wear appropriate chemical resistant clothing. Use of an impervious apron is recommended.

Other

If permissible levels are exceeded use NIOSH mechanical filter / organic vapor cartridge or an air-supplied respirator.

Respiratory protection

Wear appropriate thermal protective clothing, when necessary.

Thermal hazards

Observe any medical surveillance requirements. When using do not smoke. Always observe good personal hygiene measures, such as washing after handling the material and before eating, drinking, and/or smoking. Routinely wash work clothing and protective equipment to remove contaminants.

General hygiene considerations

9. Physical and chemical properties Appearance Gas. Physical state Aerosol. Form Not available. Color Not available. Odor Odor threshold Not available. pH Not available. Melting point/freezing point Not available. Initial boiling point and boiling range

-43.7 °F (-42.06 °C) estimated

-156.0 °F (-104.4 °C) Propellant estimated

Flash point

Not available. Not available.

Evaporation rate

Flammability (solid, gas) Upper/lower flammability or explosive limits Flammability limit - lower (%)

6.8 % estimated

9.5 % estimated

Flammability limit - upper (%)

Not available.

Explosive limit - lower (%)

Not available.

Explosive limit - upper (%)

70 - 80 psig @70F estimated

Vapor pressure

Not available.

Vapor density

Not available.

Relative density

Solubility(ies)

Not available.

Solubility (water)

Not available.

Partition coefficient (n-octanol/water)

Product name: FUSING MACHINE CLEANER Product #: 1000010986 Version #: 01 Issue date: 08-04-2016