High-Performance & High-Capacity Centrifuges Catalog
www.beckmancoultercentrifugation.com
High Performance/High Capacity Centrifugation
1
Rotor Compatibility Chart
Avanti JXN-30 Max. RPM/
Avanti JXN-26 Max. RPM/
Avanti J-26S Max. RPM/
Avanti J-E Max. RPM/ g-Force
J6-MI
Avanti J-HC
Angle Containment
g-Force
g-Force
g-Force
Fixed-Angle Rotors JA-30.50 Ti
30 000 108 860 25 000 75 600 25 000 74 200 21 000 50 400 20 000 51 500 20 000 48 400 18 000 42 100 18 000 47 900 17 000 39 800 16 000 38 400 14 000 35 000 14 000 30 100 12 000 23 200
26 000 81 800 25 000 75 600 25 000 74 200 21 000 50 400 20 000 51 500 20 000 48 400 18 000 42 100 18 000 47 900 17 000 39 500 16 000 38 400 14 000 35 000 14 000 30 100 12 000 23 200 10 000 18 500 10 000 17 700
26 000 81 800 25 000 75 600 25 000 74 200 21 000 50 400 20 000 51 500 20 000 48 400 18 000 42 100 18 000 47 900 17 000 39 500 16 000 38 400 14 000 35 000 14 000 30 100 12 000 23 200 10 000 18 500 10 000 17 700
N/A
N/A
N/A
34°
Single- or dual-locking
lid/fluid annulus
JA-25.50 †
21 000 53 300
N/A
N/A
34°
Single- or dual-locking
lid/fluid annulus
JA-25.15 †
N/A
N/A
N/A
25°
Single- or dual-locking
lid/fluid annulus
JA-21
21 000 50 400 20 000 51 500 20 000
N/A
N/A
40°
JA-20.1 †
N/A
N/A
23°
JA-20 †
N/A
N/A
34°
8 400
JA-18.1
N/A
N/A
N/A
45°
N/A
JA-18 †
16 000 37 800 17 000 39 800 16 000 38 400 14 000 35 000 14 000 30 100 12 000 23 200 10 000 18 500 10 000 17 700
N/A
N/A
23°
N/A
JA-17 †
N/A
N/A
25°
JLA-16.250 †
N/A
N/A
25°
Single- or dual-locking
lid/fluid annulus
JA-14.50 †
N/A
N/A
35°
Single- or dual-locking
lid/fluid annulus
JA-14 †
N/A
N/A
25°
JA-12 †
N/A
N/A
35°
Single- or dual-locking
lid/fluid annulus
JLA-10.500 †
N/A
N/A
N/A
20°
Sealing canister covers
JA-10
10 000 17 700
6 000 10 000 6 370 17 700
25°
JLA-9.1000
9 000
9 000
9 000
6 300 8 230
N/A
N/A
20°
Integrated bottle seal
16 800
16 800
16 800
JLA-8.1000 †
N/A
8 000
8 000
N/A
N/A
8 000
20°
Integrated bottle seal
15 970
15 970
15 970
†This rotor was tested to demonstrate containment of microbiological aerosols under normal operating conditions of the associated Beckman Coulter centrifuge, when used and maintained as instructed. Validation of the microbiological containment was done at an independent, third-party facility (CAMR, Porton Down, UK or USAMARIID, Ft. Detrick, MD, USA). Improper use or maintenance may affect seal integrity and, thus, containment.