PLENUM THERMOSTATS

Gas Furnace 15A resistive, 3 FLA, 12 LRA, 125 VA @ 120V AC. 10A resistive, 1.5 FLA, 6 LRA, 125 VA @ 240V AC. CSA approved.

Whirlpool & Maytag

SLS Series

For use in gas-fired furnaces, unit heaters and rooftop units. Features auto and manual reset. 15A resistive, 3 FLA, 12 LRA, 125 VA @ 120V AC. 10A resistive, 1.5 FLA, 6 LRA, 125 VA @ 240V AC. CSA approved. SLF & SLS Series. Features small flush mount design. SLSW Series. Features special 30mm center-to-center design.

Cooking & Gas Products

Order No.

Desc. (SPST)

Open °F

Close °F

Board Dim. In. W x H

Dishwasher, Disposer & Water Heater

Order No.

Cut Out

Cut In

1.87” Insertion Length

3/16” Vertical Terminals

SHL505 SHL506

L140-40 L170-40

140 170

100 130

1.88 x 2.8 1.88 x 2.8

SLF158VB SLF194VB SLF252VB SLF275VB SLF130VA SLF170VA SLF222VA SLF255VA SLF300VA SLF330VA

158 194 252 275 130 170 222 255 300 330 194 230 275 280 300 200 210 230 250 260 120 140 150 160 170 180 200 255 265 275 285 295 300 210 300 350

118 154 202 225 115 130 182 205 250 280 154 190 225 230 250 160 170 190 200 210 105 100 110 120 130 140 160 205 215 225 235 245 250 170 250 300

Laundry

3.12” Insertion Length

SHL501 SHL502 SHL503 SHL504 SHL507 SHL508 SHL509 SHL510* SHL511* SHL512* SHL513* SHL514* SHL515* SHL516* SHL517* SHL518*

L170-40 L180-30 L190-40 L240-40 L140-30 L190-20 L240-30 L150-20 L160-20 L170-20 L170-40 L180-40 L200-40 L210-40 L220-40 L250-40

170 180 190 240 140 190 240 150 160 170 170 180 200 210 220 250

130 150 150 200 110 170 210

1.88 x 2.8 1.88 x 2.8 1.88 x 2.8 1.88 x 2.8 1.88 x 2.8 1.88 x 2.8 1.88 x 2.8

1/4” Vertical Terminals

Refrigeration

Fittings, Venting & Installation

130 1.625 x 1.44 140 1.625 x 1.44 150 1.625 x 1.44

3/16” Horizontal Terminals

SLF194HB SLF230HB SLF275HB SLF280HB SLSW300HB SLF200HA SLF210HA SLF230HA SLF250HA SLF260HA

130 140 160 170 180 210

1.88 x 2.94 1.88 x 2.94 1.88 x 2.94 1.88 x 2.94 1.88 x 2.94 1.88 x 2.94

Electrical

Plumbing

1/4” Horizontal Terminals

7.12” Insertion Length

SHL519

L155-30

155

125

1.88 x 2.8

Property Maintenance

* Includes gasket.

Unit#3078019

LIMIT CONTROLS

45° 1/4” Terminals

Gas Furnace

SLS120 SLS140 SLS150 SLS160 SLS170 SLS180 SLS200 SLS255 SLS265 SLS275 SLS285 SLS295 SLS300

Motors

Features manual reset. Open on rise. Includes adapter flange plate. 25A resis- tive, 14 FLA, 72 LRA, 125 VA @ 120V AC. 25A resistive, 10A FLA, 60A LRA, 125 VA @ 240V AC.

HVAC/R

Order No.

Open

SHM125 SHM130 SHM160 SHM170 SHM180 SHM190 SHM200 SHM290 SHM350

125 130 160 170 180 190 200 290 350

Chemicals

Charging, Recovery & Welding

SLSW210 SLSW300 SLSW350

Test Equip., Tools & Service Acc.