AOAC SPIFAN Stakeholder Program Meeting Book (September 10, 2020)
Working group activities
Discussed during the calls • Working Group had experience and answers to questions because of the 2’FL and LNnT SMPRs : e.g. selectivity/interferences; (non available) reference materials • The “main body text” of the 2’FL and LNnT – approved – SMPRs kept as template
• Emphasis was given to:
Analytical range per HMO Æ mainly based on data for breast milk
9
Specific Performance Claims: 6’-SL Table 1: Method Performance Requirements a Analytical range 2 – 150 mg/100g Limit of Quantitation (LOQ) ≤ 1.6 mg/100g
85-110% (2-20 mg/100g) 90-110% (>20mg/100g)
Recovery
Repeatability (% RSD r )
≤ 5%
Reproducibility (% RSD R ) ≤ 10% a Concentrations apply to: i) “ready-to-feed’ liquids “as is”; ii) reconstituted powders (25 g into 200 g of water); and iii) liquid concentrates diluted 1:1 by weight.
10
Made with FlippingBook Publishing Software