The key to battery longevity lies in a thorough understanding of the status of individual batteries in a multi-battery pack in terms of their duty cycles and load factors. Battery maintenance should be at the top of a UPS

the input side of a UPS – the filter/rectifier siting. Regular maintenance regimens will most certainly be able to determine whether damage has occurred and remedial steps can be initiated. This applies to almost all elements of a UPS system, The scourge of Highveld weather, lightning, can do

user’s priority list. A good maintenance regimen will help prolong battery life while keeping a note of where the battery is in its life cycle will provide an indication as to when failure is im- minent. Battery balancing The prevalence of unexpected power outages in South Africa – often longer than four hours – has exposed one of the Achilles’ heels of standby power devices; the dramatically shortened lifespan of batter- ies (including deep-cycle batteries) when subjected to full depletion on a regular basis. To help prevent premature battery failure, a new-generation, battery management harness is a necessity. The ‘smart’ battery technology in leading harness brands monitors and optimises the performance and efficiency of individual batteries in a battery pack on a 24x7 basis. This is achieved by a dedicated, computerised battery balanc- ing solution that automatically monitors data streams containing information critical to the wellbeing of individual batteries, including temperature, state of charge and depth of discharge. The tally of the number of discharge/ charge cycles is recorded. Using this data, the system’s battery performance is able to be balanced and equalised. Should an individual battery’s operating parameters not meet design specifications or fail for any reason the battery is flagged for replacement – thus ensuring the integrity of the pack. The technology featured in a battery management harness not only distributes and balances the battery load, but discharge and charge regimes across all batteries in the pack can be monitored on a minute-by-minute basis. Thus steps can be timeously taken to ensure that no battery is compromised through over-cycling or a malfunction of any kind. UPS threats Apart from battery failure, other serious threats to the smooth opera- tion of a UPS system include a sudden ‘spike’ in the power supply. Called transient spikes, they are likely to inflict serious damage to

serious damage to a UPS system and to the highly sensitive computer systems it is tasked to protect. A common misconception is that a UPS system constantly protects itself and the equipment load from lightning strikes. If the amount of energy in the transient (the lightning strike) is large enough, damage will occur.   Surge sup- pression devices, if installed, including metal oxide varistor (MOV) devices are often compromised by lightning strikes. As small as a two-rand coin or as large as a cool-drink can, capaci- tors, like batteries, degrade over time. The effects of time may not be apparent, but a single failure will have a domino effect, leaving the other capacitors to work harder and fail sooner. Most UPS systems contain as many as a dozen or more of these simple devices that store and release electrical energy. Dust is the enemy, steadily advancing to block filters and cause progressive overheating of UPS systems. Regular monthly inspec- tions are required to address this problem. Fortunately, filters are the least most expensive components of an effective UPS maintenance plan. Contactor failure is another threat to UPS systems. Contactors, which are also prime collectors of fine dust and other resistive par- ticles, require regular inspection and cleaning to ensure optimum performance and to guard against premature failures. The failure-proofing of relays is not usually at the top of any maintenance schedule, however, technically-aware UPS owners understand that the sticking of welded relays may go unnoticed for long periods of time. The problem is revealed only when emergency change-of-state events occur. Appropriate inspection procedures are able to detect problems before they arise. Total cost of ownership Selecting a UPS system that matches an organisation’s exact needs is vital to UPS longevity. Consulting a knowledgeable provider with experience in the UPS industry before making an investment is pru- dent as is selecting a system that can organically grow in tandem with the company’s expansion plans. In this light, when budgeting for a UPS system, it is crucial to consider the total cost of ownership (TCO) – rather than just the