BuyLog Flippingbook OCT 2024 v2
RV POWER PEDESTALS AND INLETS, BUYLOG SECTION 3
3-5
— Ordering tables
Unmetered surface mount
Ground fault circuit breaker
Wire range table 1
Ordering code
Volts
Receptacles 30A/20A GFCI 50A/20A GFCI
Circuit protection THQL1130, THQL1120 THQL2150, THQL1120 THQL2150, THQL1130, THQL1120
Head type Lighted
Amps
100 120/240
N/A Single Side N/A Single Side
No No
1 GE1LU032SS 2 GE1LU502SS
70
120/240
100 120/240 50A/30A/20A GFCI
N/A Single Side
No
3 GE1LU532SS
— Unmetered surface mount
Ring type metered surface mount
Ground fault circuit breaker
Wire range table 1
Ordering code
Volts
Receptacles 30A/20A GFCI 50A/20A GFCI
Circuit protection THQL1130, THQL1120 THQL2150, THQL1120 THQL2150, THQL1130, THQL1120
Head type Lighted
Amps
100 120/240
N/A Single Side N/A Single Side N/A Single Side
No No No
2 GE1LM032SS 2 GE1LM502SS 4 GE1LM532SS
70
120/240
100 120/240 50A/30A/20A GFCI
Unmetered pad mount post
Ground fault circuit breaker
Wire range table 1
Ordering code
Volts
Receptacles
Circuit protection
Head type Lighted
Amps
100 120/240 50A/30A/20A GFCI
THQL2150, THQL1130, THQL1120 THQL2150, THQL1130, THQL1120 THQL2150, THQL1130, THQL1120
N/A Back-to-Back
No
5 GE1LU532PB
100 120/240 50A/30A/20A GFCI
N/A Single Side
No
6 GE1LU532PS
100 120/240 50A/30A/20A GFCI
N/A Single Side
Yes
6 GE1LU532PSL
Ring type metered pad mount post
Ground fault circuit breaker
Wire range table 1
Ordering code
Volts
Receptacles
Circuit protection
Head type Lighted
Amps
100 120/240 50A/30A/20A GFCI
THQL2150, THQL1130, THQL1120
N/A Single Side
No
7 GE1LM532PS
— Ring type metered pad mount post
Unmetered earth burial post
Ground fault circuit breaker
Wire range table 1
Ordering code
Volts
Receptacles 30A/20A GFCI 30A/20A GFCI
Circuit protection THQL1130, THQL1120 THQL1130, THQL1120 THQL2150, THQL1130, THQL1120 THQL2150, THQL1130, THQL1120 THQL2150, THQL1130, THQL1120GFT THQL2150, THQL1130, THQL1120 Circuit protection THQL1130, THQL1120 THQL2150, THQL1130, THQL1120 THQL2150, THQL1130, THQL1120 THQL2150, THQL1130, THQL1120GFT THQL2150, THQL1130, THQL1120
Head type Lighted
Amps
70 70
120/240 120/240
N/A Single Side N/A Single Side N/A Back-to-Back
No
6 GE1LU032ES 6 GE1LU032ESL 5 GE1LU532EB
Yes
100 120/240 50A/30A/20A GFCI
No
100 120/240 50A/30A/20A GFCI
N/A Single Side
No
6 GE1LU532ES
100 120/240
50A/30A/20A
20A
Single Side
No
6 GE1LU532ESG
100 120/240 50A/30A/20A GFCI
N/A Single Side
Yes
6 GE1LU532ESL
Ring type metered earth burial post
Ground fault circuit breaker
Wire range
Volts
Receptacles 30A/20A GFCI
Head type Lighted
table Ordering code
Amps
100 120/240
N/A Single Side N/A Back-to-Back
No No
7 GE1LM032ES 8 GE1LM532EB
100 120/240 50A/30A/20A GFCI
100 120/240 50A/30A/20A GFCI
N/A Single Side
No
7 GE1LM532ES
100 120/240
50A/30A/20A
20A
Single Side
No
7 GE1LM532ESG
100 120/240 50A/30A/20A GFCI
N/A Single Side
Yes
7 GE1LM532ESL
Made with FlippingBook - professional solution for displaying marketing and sales documents online