Molded Case Circuit Breakers

Section 6

Record Plus ™ Molded Case Circuit Breakers Record Plus ™ represents the very latest in molded case circuit breaker design. Utilizing design features such as double-break rotary contact structures and advanced ablative materials to enhance interruption, Record Plus ™ is capable of interrupting ratings up to 200kA. High kAIC ratings, selective coordination, reduced arc flash energy, and current limitation embody the core design principles of Record Plus ™ . FC 100 and FB 100 circuit breakers are supplied with factory installed non-user interchangeable thermal-magnetic trip units and can be supplied with or without lugs. FB breakers are avail- able in 1-, 2- and 3-pole versions. FC is available in 2- and 3-pole versions, both in a 3-pole footprint. FE 250 circuit breakers are supplied with factory installed, non-user interchangeable PremEon S electronic trip units that feature the use of front accessible, user adjustable dials to establish or change the breaker’s amp rating. Adjustable instantaneous with tracking short-time is standard. Ground fault protection is optional. FE is available in 2- or 3-pole versions, both in a 3-pole footprint. FG 600 circuit breakers are supplied with factory installed, non- user interchangeable electronic trip units. Customers can select from the PremEon S or SMR2 electronic trip units. PremEon S features the use of front accessible, user adjustable dials to establish or change the breaker’s amp rating. Adjustable instantaneous with tracking short-time is standard. Ground fault protection is optional. SMR2 uses rating plugs to establish or change the breaker’s amp rating. Rating plugs are user specified and ordered under separate product number. SMR2 allows individual adjustment of Long-Time delay, Short-Time pickup and Delay, and Ground Fault Pickup and Delay (if so equipped). Zone Selective Interlocking (ZSI), Ground Fault Alarm, and Modbus Communications are also available via the SMR2’s interface. FG is available in 2- and 3-pole versions, both in a 3-pole footprint. All frames use common internal accessories (auxiliary switches, UV releases, shunt trips, and bell alarms) UL listed for field installation. UL listed maximum short circuit ratings at 480VAC are 150kA for the 100A frames, 100kA for the 250A frame and 200kA for the 600A frames. Unless noted otherwise, all circuit breakers and accessories are listed in UL file number E11592.

Record Plus ™ Molded Case Circuit Breakers

Other MCCB Features —UL489/cUL489 Listed

—Broad product line to meet virtually any application need. —Reduced downtime. A tripped breaker is easily spotted and can be immediately reset after the fault has been corrected. —Eliminates single phasing. A common trip bar disconnects all poles simultaneously on both overloads and short circuits. —Offers application flexibility through the use of a wide variety of accessory devices and special attachments. —Repetitive operation—no fuses to replace. —Breakers can be repetitively tested. Fuses must be destroyed to confirm calibration accuracy. For more information on these products, order publications listed in Sections 27 and 28.

Rev. 1/19 Data subject to change without notice

go.abb/industrial

GE Products BuyLog

6-5

Made with FlippingBook - Online magazine maker